10
This feature allows the installer to bias the
thermostat calibration and temperature
shown on the display. The unit is pre-set
to 0. Using the
+
or
-
buttons select your
preference. The options are + or - 3°C in
0.5°C increments.
Press the
PROG
button to return to RUN mode.
Setting Thermostat Calibration
(option 5)
Installa
tion Instruc
tions
GB
or
+
-
Security settings should be carried out at the last stage of the
commissioning process. This is an optional setting and need
only be carried out if the building owner wishes to prevent the
user from tampering with the thermostat programmes.
This is achieved by setting the
advanced programming option 1 to
keyboard disabled ON. This disables all
programming functions and limits the
temperature overrides to ± 2°C. All user features such as choice
of clock display (AM/PM or 24 hour), temperature scaling (°F
or °C) continue to be available to the user. To make the setting
refer to the setting the keyboard disable function paragraph on
page 8.
Security Settings