![Danfoss H1 078 Service Manual Download Page 8](http://html1.mh-extra.com/html/danfoss/h1-078/h1-078_service-manual_3664242008.webp)
Cross section view
Swashplate
Cylinder block
Auxiliary mounting pad “B”
Charge pump
Servo piston
Piston
Shaf t seal
Shaf t
Slippe r
Electric displacement control
P106 045E
Valve plate
Swashplate feedback pin
The System Circuit
The Basic Closed Circuit
Hydraulic lines connect the main ports of the pump to the main ports of the motor. Fluid flows in either
direction from the pump to the motor and back. Either of the hydraulic lines can be under high pressure.
In pumping mode the position of the pump swashplate determines which line is high pressure as well as
the direction of fluid flow.
Case Drain and Heat Exchanger
The pump and motor require case drain lines to remove hot fluid from the system. The pump and motor
drain from the topmost port to ensure the cases remain full of fluid. The motor case drain can connect to
the lower drain port on the pump housing or it can tee into the case drain line upstream of the heat
exchanger. A heat exchanger with bypass valve cools the case drain fluid before it returns to the
reservoir.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Introduction
8 |
©
Danfoss | May 2018
520L0848 | AX00000087en-US0308