MDC Legend - single pumps
Wrench size and torque
Item
Description
Wrench size
Torque
D065
O-ring plug
3/16 internal hex
12 N•m [9 lbf•ft]
D084
screen
-
-
D098
ring
-
-
D200
feedback pin
13 mm deep well socket
22.5-27.5 Nm [16.6-20.3 lbf•ft]
D250
cap screw
5 mm internal hex
13.3 Nm [9.8 lbf•ft]
D80
solenoid
-
-
D81
Oring
-
-
D750
neutral start switch
-
-
D751
Oring
-
-
D735
plug
3/4 inch
30 Nm [22 lbf•ft]
F00A
servo orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
F00B
servo orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
F00P
supply orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
F00T
tank orifice
3 mm internal hex
2.5 Nm [1.8 lbf•ft]
Inspection
Inspect the machined surfaces on the control and top of the pump. If you find any nicks or scratches,
replace the component.
Reassembly
Ensure you install dowel pins (D300) in the housing before installing the control.
1. Install a new gasket (D150).
2. Install dowel pins (D300) in the housing.
W
Warning
If the feedback pin comes off during operation, the pump will lose controllability causing a
potentially hazardous situation. Insure feedback pin is properly torqued before continuing with
reassembly.
3. If you removed screen (D084), install a new one. Install it with the mesh facing outward (see drawing).
Install retaining ring (D098).
MDC - Proper screen orientation
D084
D084
Incorrect screen
orientation
Correct screen
orientation
D098
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
44 |
©
Danfoss | May 2018
520L0848 | AX00000087en-US0308