3. Operate vehicle/machine through full range of controls to ensure proper operation.
Charge Pressure Relief Valve
P106 040E
V010
V024
22 mm
52 N•m
[38 lbf•ft]
Pressure Limiter Valve Replacement
Replace the pressure limiter valve as a complete unit. Do not attempt to repair individual components.
See Pressure Limiter Adjustment, page 32, for adjustment instructions.
Removal
Using a 22 mm wrench, remove the pressure limiter valve (L100). Discard O-ring.
Inspection
Inspect the sealing surfaces of the pump for nicks or scratches.
Reassemby
1. Install new O-ring. Lubricate O-ring with petroleum jelly.
2. Replace pressure limiter valve. Torque to the value in the table below.
3. Operate pump at full range of controls to ensure proper machine operation.
Pressure limiter is available as complete unit only. O-ring is available separately.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
60 |
©
Danfoss | May 2018
520L0848 | AX00000087en-US0308