background image

Danfoss FT1555-BM230 Bench Mount Hose Capping System Operator’s Manual

AQ453954047097en-010101

© Danfoss FT1555-BM230 Bench Mount Hose Capping System Operator’s Manual | 2023.04. | 3

Important Information

         Before attempting to use the FT1555-BM230, read, understand, 
and know all the safety information in this chapter.  If you do not 
follow all the warnings and procedures in this manual, it could lead 
to serious injury to yourself or others. This CapSeal System was 
designed with safety in mind and includes features to help prevent 
injury and damage. This manual is intended to help you operate 
the units in a safe manner. The operator / user is a person who 
physically interacts with the unit and/or the unit’s control systems.  
In this manual an operator / user includes a person who cleans the 
machine. It is your responsibility to operate this system

in accordance with all the safety instructions and procedures in this 
manual and with all other safety procedures in your workplace.  It 
is the user’s responsibility to make sure that the system is correctly 
installed, configured, commissioned, operated, serviced, and 
maintained so that such actions are only carried out by people 
who have been properly trained for those tasks.  It is also the user’s 
responsibility to make sure that the machine is only used in full 
accordance with laws - and regulations, which have the force of law 
- in the jurisdiction in which the machine is installed.

Intended Use

The FT1555-BM230 is intended to only shrink CapSeal Capsules 
onto a hose or tube fitting. Applications other than intended use 
may void warranty.

Packaging

The CapSeal Machine is packed in cardboard for protection during 
transportation. Remove all packaging materials before usage. 
Dispose or recycle all packaging materials in accordance with the 
local regulations.

General

When the machine is delivered, check the equipment for possible 
transport damage and that all components are included. 

Included Contents:

• 

CapSeal System FT1555-BM230

• 

CE manual

• 

FT1555-SMP (Small Magnetic Puck)

• 

FT1555-LMP (Large Magnetic Puck)

!

Safety

Description of safety symbols in this manual

Safety and Warning signs are attached to the machine to give safety information. 
All Safety/Warning signs are repeated and usually further explained in this manual.

Mandatory:

 Read User Manual before using this system.

Use eye-protection

Caution! 

Burning hands or fingers when entering Air Knife

 Caution! 

General warning sign

Caution! 

Hot surface

Caution! 

Electrical hazard

!

Summary of Contents for FT1555-BM230

Page 1: ...Operator s Manual Danfoss FT1555 BM230 Bench Mount Hose Capping System...

Page 2: ...formation 3 Description of safety symbols in this manual 3 Safety Symbols on the machine 4 Safety Precautions 4 Residual Risks 4 Description and Operating Procedures 5 Product Views FRONT BACK SIDE 5...

Page 3: ...ons are only carried out by people who have been properly trained for those tasks It is also the user s responsibility to make sure that the machine is only used in full accordance with laws and regul...

Page 4: ...e routine preventive maintenance program is up to date If any part of the system is known or suspected to be defective or wrongly adjusted do not use the system until a repair has been made Operation...

Page 5: ...mm ID through 80mm ID Works with fitting hex sizes from 10mm through 78mm or any other shape fitting within the size limitation of the capsule The Air Knife with heat guard has a 110mm center opening...

Page 6: ...t the machine will take 8 minutes to reach the optimal sealing temperature Consult Chart Below Place the CapSeal Capsule over the fitting of the hose or tube assembly Place small or large puck onto th...

Page 7: ...m to 32mm 1 07 to 1 26 x 38X40 30mm to 36mm 1 19 to 1 42 x x 43X45 32mm to 41mm 1 26 to 1 61 x x 46X50 34mm to 44mm 1 34 to 1 73 x x 52X60 41mm to 50mm 1 62 to 1 97 x x 58X60 49mm to 56mm 1 93 to 2 20...

Page 8: ...FRACTIONAL ANGULAR MACH BEND TWO PLACE DECIMAL THREE PLACE DECIMAL APPLICATION USED ON NEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF INSERT C...

Page 9: ...e filter and air intake grill is required when the machine is in use If you have any questions or concerns about the cleaning procedures or correct operation of the unit please contact us immediately...

Page 10: ...al System Bumper Feet 13 FT1555 SMP Small Puck FT1555 LMP Large Puck Problem Cause Solution Capsule does not fit properly Wrong diameter capsule for application Measure outside diameter of the fitting...

Page 11: ...alterations to the machine could lead to serious personal injury Please call Danfoss with any questions regarding the safe operation of the FT1555 BM230 Disposal Electrical and electronic equipment ac...

Page 12: ...ons FC Danfoss hoses fittings and tooling provide the ultimate fluid conveyance solutions for a variety of equipment and applications around the world We proudly engineer to support a sustainable futu...