FC 300 Profibus
Parameters
9-15 PCD Write Configuration
Array [10]
Option:
None
[3]
3-02 Minimum Reference
[3]
3-03 Maximum Reference
[3]
3-12 Catch Up/Slow Down Value
[3]
3-41 Ramp 1 Ramp Up Time
[3]
3-42 Ramp 1 Ramp Down Time
[3]
3-51 Ramp 2 Ramp Up Time
[3]
3-52 Ramp 2 Ramp Down Time
[3]
3-80 Jog Ramp Time
[3]
3-81 Quick Stop Ramp Time
[3]
4-11 Motor Speed Low Limit
[RPM]
4-13 Motor Speed High Limit
[RPM]
4-16 Torque Limit Motor Mode
[RPM]
4-17 Torque Limit Generator Mode
[RPM]
8-90 Bus Jog 1 Speed
[RPM]
8-91 Bus Jog 2 Speed
[RPM]
16-80 Fieldbus CTW 1
[RPM]
16-82 Fieldbus REF 1
[RPM]
Function:
Assigns different parameters to PCD 3 to 10 of the
PPO’s (the number of PCD’s depends on the PPO
type). The values in PCD 3 to 10 are written to the
selected parameters as data values.
9-16 PCD Read Configuration
Array [10]
Option:
None
[RPM]
16-00 Control Word
[RPM]
16-01 Reference [Unit]
[RPM]
16-02 Reference %
[RPM]
16-03 Status Word
[RPM]
16-05 Main Actual Value [%]
[RPM]
16-10 Power [kW]
[RPM]
16-11 Power [hp]
[RPM]
16-12 Motor Voltage
[RPM]
16-13 Frequency
[RPM]
16-14 Motor Current
[RPM]
16-16 Torque
[RPM]
16-17 Speed [RPM]
[RPM]
16-18 Motor Thermal
[RPM]
16-19 KTY Sensor Temperature
[RPM]
16-20 Phase Angle
[RPM]
16-30 DC Link Voltage
[RPM]
16-32 Brake Energy / s
[RPM]
16-33 Brake Energy / 2 min
[RPM]
16-34 Heatsink Temp.
[RPM]
16-35 Inverter Thermal
[RPM]
16-38 SL Controller State
[RPM]
16-39 Controlcard Temp.
[RPM]
16-50 External Reference
[RPM]
16-51 Pulse Reference
[RPM]
16-52 Feedback [Unit]
[RPM]
16-53 Digi Pot Reference
[RPM]
16-60 Digital Input
[RPM]
16-61 Terminal 53 Switch Setting
[RPM]
16-62 Analog Input 53
[RPM]
16-63 Terminal 54 Switch Setting
[RPM]
16-64 Analog Input 54
[RPM]
16-65 Analog Output 42 [mA]
[RPM]
16-66 Digital Output [bin]
[RPM]
16-67 Freq. Input #29 [Hz]
[RPM]
16-68 Freq. Input #33 [Hz]
[RPM]
16-69 Pulse Output #27 [Hz]
[RPM]
16-70 Pulse Output #29 [Hz]
[RPM]
16-84 Comm Option STW [Binary]
[RPM]
16-85 FC port CTW 1 Signal
[RPM]
16-90 Alarm Word
[RPM]
16-91 Alarm Word 2
[RPM]
16-92 Warning Word
[RPM]
16-93 Warning Word 2
[RPM]
16-94 Extended Status Word
[RPM]
16-95 Extended Status Word 2
[RPM]
Function:
Assigns different parameters to PCD 3 to 10 of the
PPO’s (the number of PCD’s depends on the PPO
type). PCD 3 to 10 holds the actual data value of
the selected parameters.
9-18 Node Address
Range:
0 - 126
*
126.
Function:
Sets the station address. You can also set it on a
hardware switch. You can set the address in par.
9-18 only if the hardware switch is set to 126 or
127. The parameter displays the actual setting of
the switch when setting the hardware switch to
>0 and <126 . Power-up or updating par. 9-72
changes par. 9-18.
9-22 Telegram Selection
Option:
*
Standard telegram 1
[1]
PRO 1
[101]
PRO 2
[102]
PRO 3
[103]
PRO 4
[104]
PRO 5
[105]
61