6.5 Micrometer adjustment
If the measured forming dimensions of the workpiece deviate from
the forming dimensions of the crimping die when the micrometer is
set to zero, the micrometer must be readjusted.
1.
Release the screws on the cover.
2.
Remove the cover (see “Annex” in Section 9).
3.
Loosen the counter-nut (1) of the contact screw (2).
4.
Adjust the contact screw (2).
2.5 revolutions of the contact screw correspond to 1 mm change in
the forming dimension.
V
5.
Remount the enclosure/front panel.
6.
Test the crimping process and readjust if necessary.
Summary of Contents for ET4400
Page 1: ......
Page 3: ......
Page 53: ...Hydraulic oil changes and wear part replacements must be recor ded in the maintenance log ...
Page 75: ...Retaining bolt Crimping die profile 262 263 239 266 232 237 554 245 246 247 245 114 4 x x x ...
Page 76: ...9 6 Hydraulic diagram ...
Page 77: ...9 7 Electric diagram 380 V 50 60 Hz 3 phases ...
Page 78: ...230 V 50 60 Hz 1phase ...
Page 80: ......
Page 82: ......
Page 83: ......
Page 84: ......