Troubleshooting
Problem
Probable cause
Remedy
Compressor does not start
Faulty frequency table
Wrong / loose connection of frequency cable
Check the frequency cable continuity.
Check the connection of frequency cable at
controller and drive side
Fan does not start
Door is open or door contact is defective
Fan stops when door is opened
Check that door contact is ok
Defrost does not start
Controller in pull down mode
Defrost might be delayed during pull down
Check parameter Pud->Pdi
Alarm does not sound
Alarm delayed
Check ALA->Htd, Abd
Check Pud->Pdd
Display brightness is weak
Ambient light sensor broken
Replace sensor
Shift between ECO and normal
mode does not
happen on ambient light change
Ambient light sensor broken
or light level not set properly
Check Eng->SLd, SLn
Display alternates between condenser and
temperature
Condenser too hot
Clean condenser
Check Con ->CAL, CbL
Display alternates between high and
temperature
Temperature too high
Check ALA->HAt
Display alternates between low and
temperature
Temperature too low
Check ALA -> LAt
Display shows "
dEf
"
Defrost in progress
Check diS ->SdF
Alarm
code
Trigger
Automatic
clearance
Outputs
Comments
"Hi"
Air temperature is higher than
"
ALA->Hat
" for "
ALA->Htd
"
User configured
Blink "
Hi
" with the highest temperature; If configured:
cut in alarm relay, beep the buzzer
High temperature alarm
"Lo"
Air temperature is lower than
"
LAt
" for "
Ltd
"
User configured
Blink "
Lo
" with the lowest temperature. If configured:
cut in alarm relay, beep the buzzer
Low temperature alarm
"Con"
Condenser temperature is too
high or too low
User configured
Blink "
Con
". If configured: cut in alarm relay, beep the buzzer
Condenser alarm
"dor"
Door open for more than
"
ALA -> dod
"
Always
Blink "
dor
". If configured: cut in alarm relay, beep the buzzer
Door open alarm
"uHi"
Line voltage is higher than
"
Cop->uHi
"
Always
Blink "
uHi
". If configured: cut in alarm relay, beep the buzzer
High voltage alarm
"uLi"
Line voltage is lower than
"
Cop->uLi
"
Always
Blink "
uLo
". If configured: cut in alarm relay, beep the buzzer.
Low voltage alarm
"LEA"
Compressor continuous
running for more than
"
ALA->LEA
"
Always
Blink "
LEA
". If configured: cut in alarm relay, beep the buzzer
Leakage alarm
"E01"
"
S1
" error
Always
Blink "
E01
". If configured: cut in alarm relay, beep the buzzer
"
S1
" sensor failure
(short or open)
"E02"
"
S2
" error
Always
Blink "
E02
". If configured: cut in alarm relay, beep the buzzer
"
S2
" sensor failure
(short or open)
"E03"
"
S3
" error
Always
Blink "
E03
". If configured: cut in alarm relay, beep the buzzer
"
S3
" sensor failure
(short or open)