"EoF"
Min. 0 Hz
Max. 200 Hz
Default 100 Hz
Frequency during Sensor error
Frequency at which compressor must run during cab air sensor error. In case of cab air sensor error controller will send this
frequency to compressor drive during Error run time "Ert". and during error stop time it will send the Off frequency "CoF"
"Ert"
Min. 0 min
Max. 60 min
Default 5 min
Error Run Time
This parameter only become active in the unlikely event of cabinet air sensor error. Ert define the duration the refrigeration
system will run during cab air sensor error.
Example: "Ert=4" [min] and "ESt=16" [min] will provide an average cooling system activity of 20%. Ert and "ESt" values must be
configured based on OEM experience
"ESt"
Min. 0 min
Max. 60 min
Default 5 min
Error Stop Time
This parameter only become active in the unlikely event of cabinet air sensor error. ESt define the duration the refrigeration
system will stop during cab air sensor error
"CSt"
Min. 0 min
Max. 30 min
Default 2 min
Minimum Stop Time
It determines the minimum number of minutes the compressor must remain idle before a Temperature cut-in can take effect. For
example, if the temperature sensor indicates that the cut-in temperature has been reached, but the number of minutes set in this
parameter have not elapsed since the compressor last stopped, then the compressor will stay OFF.
It will only start once the duration given by "
CSt
" has been reached provided the temperature is still high enough. "
CSt
" thus
overrides the cut-in.
"Crt"
Min. 0 min
Max. 30 min
Default 0 min
Minimum Run Time
It determines the minimum number of minutes the compressor must run before a Temperature cut-out can take effect. For
example, if the temperature sensor indicated that the cut-out temperature has been reached, but the number of minutes set in
this parameter have not elapsed since the compressor last started, then the compressor will continue. It will only stop once the
duration given by "
Crt
" has been reached – provided the temperature is still low enough.
"
Crt
" thus overrides the cut-out.
"uSt"
Min. 0 sec
Max. 30 sec
Default 1 sec
Minimum On time at Start Speed
Minimum time the compressor must run at start speed
"Cdd"
Min. 0 min
Max. 15 min
Default 15 min
Compressor Door Open Delay/Cdd
This parameter sets the delay in minutes before the compressor stop frequency signal
when the door is opened. If set to 15, the function is disabled.
"Srt"
Min. 0 min
Max. 60 min
Default 0 min
System resume after door open
Fan and Compressor resume after cut out by door open.
Con
Condenser Protection settings
NOTE: A condensor temperature sensor is required to use these parameters.
Condenser protection is generally used in dusty environments where
the condenser may accumulate a layer of dust or dirt and therefore be
at risk of overheating.
"CAL"
Min. 0°C
Max. 200°C
Default 80°C
Condenser Alarm Limit/CAL
This parameter sets the temperature for the condenser at which an alarm
will be generated.
"CbL"
Min. 0°C
Max. 200°C
Default 85°C
Condenser Block Limit/CbL
This parameter sets the temperature which if reached will cause the
compressor to switch OFF.
"CoL"
Min. 0°C
Max. 200°C
Default 60°C
Condenser OK Limit/CoL
This parameter sets the temperature at which the compressor is
allowed to start again after the temperature set in "
CbL
" above has been
exceeded and the compressor stopped.