![background image](http://html1.mh-extra.com/html/danfoss/em-pmi540-t4000/em-pmi540-t4000_user-manual_3436468042.webp)
Recommended cable types for low voltage connections
Application
Cable type
Resolver cabling
Shielded cable (twisted pair)
Temperature measurement (PT100)
Shielded cable (twisted pair)
Location of the low voltage connectors of the machine
1 Low voltage (measurement signal) connector including winding temperature sensors and resolver connections.
Type: Deutch HD34-24-47PE
2 Bearing temperature measurement sensor connector in the N-end of the machine. Type: M12 Male 4-pin, A-coded
connector.
3 Bearing temperature measurement sensor connector in the D-end of the machine. Type: M12 Male 4-pin, A-coded
connector.
Low voltage connector details
Deutsch HD34-24-47PE connector has two kinds of mating pins: 1 mm and 1.5 mm in
diameter.
User Guide
EM-PMI540-T4000
Installation
42 |
©
Danfoss | April 2023
BC265857716810en-000202