background image

4

Instructions

RI.8B.G1.52

©

Danfoss

05/2000

 EKC 

366

ENGLISH

Literature survey:
Manual EKC 366

RS.8A.D-.--

Installation guide, Data communication link

RC.8A.C-.--

The buttons

When you want to change a setting, the two buttons will give
you a higher or lower value depending on the button you are
pushing. But before you change the value, you must have
access to the menu. You obtain this by pushing the upper
button for a couple of seconds - you will then enter the
column with parameter codes. Find the parameter code you
want to change and push the two buttons simultaneously.
When you have changed the value, save the new value by
once more pushing the two buttons simultaneously.

Gives access to the menu

Gives access to changes

Saves a change

LED’s on the front panel

There is one LED on the front panel which will light up when
power is sent to the pilot valve.
There are furthermore three LED’s which will flash if there is
an error in the regulation. In this situation you can show the
error code on the display and cut out the alarm by giving the
upper button a brief push.

Display

The values will be shown with three digits, and with a setting
you can determine whether they are to be shown in °C or in
°F.

Operation

Examples of operations

Set the valve’s basic temperature reference
1. Push the two buttons simultaneously
2. Push one of the buttons and select the new value
3. Push both buttons again to conclude the setting

Read the valve’s regulating reference
1. Push the lower button

(After approx. 20 seconds the controller automatically
returns to its setting, and it again shows the valve’s actual
temperature)

Set one of the other menus
1. Push the upper button until a parameter is shown
2. Push one of the buttons and find the parameter you want to

change

3. Push both buttons simultaneously until the parameter value

is shown

4. Push one of the buttons and select the new value
5. Push both buttons again to conclude the setting

Menu survey

n

o

i

t

c

n

u

F

-

a

r

a

P

r

e

t

e

m

.

n

i

M

.

x

a

M

)

y

a

l

p

s

i

d

d

r

a

d

n

a

t

s

(

e

r

u

t

a

r

e

p

m

e

t

l

a

u

t

c

a

s

e

v

l

a

v

d

a

e

R

-

C

°

e

c

n

e

r

e

f

e

r

e

r

u

t

a

r

e

p

m

e

t

c

i

s

a

b

s

e

v

l

a

v

t

e

S

-

C

°

0

.

0

4

C

°

0

4

1

e

c

n

e

r

e

f

e

r

n

o

i

t

a

l

u

g

e

r

s

e

v

l

a

v

d

a

e

R

-

C

°

)

F

°

/

C

°

(

t

i

n

u

e

r

u

t

a

r

e

p

m

e

t

t

c

e

l

e

S

5

0

r

C

°

F

°

e

c

n

e

u

l

f

n

i

e

r

u

t

a

r

e

p

m

e

t

s

’l

a

n

g

i

s

t

u

p

n

I

6

0

r

K

9

.

9

9

-

K

9

.

9

9

s

s

e

r

d

d

a

s

r

e

ll

o

r

t

n

o

C

*

3

0

o

1

0

6

)

e

g

a

s

s

e

m

n

i

p

-

e

c

i

v

r

e

s

(

h

c

t

i

w

s

F

F

O

/

N

O

*

4

0

o

-

-

l

a

n

g

i

s

t

u

p

n

i

e

n

i

f

e

D

l

a

n

g

i

s

o

n

:

0

A

m

0

2

-

4

:

1

A

m

0

2

-

0

:

2

V

0

1

-

0

:

3

V

0

1

-

2

:

4

0

1

o

0

4

,

h

c

n

e

r

f

=

2

,

n

a

m

r

e

G

=

1

,

h

s

il

g

n

E

=

0

(

e

g

a

u

g

n

a

L

)

h

s

i

d

e

w

S

=

6

,

h

s

i

n

a

p

S

=

4

,

h

s

i

n

a

D

=

3

*

1

1

0

0

6

y

c

n

e

u

q

e

r

f

e

g

a

t

l

o

v

y

l

p

p

u

s

t

e

S

2

1

o

z

H

0

5

z

H

0

6

n

o

i

t

a

m

r

o

f

n

i

e

c

i

v

r

e

S

l

a

n

g

i

s

t

n

e

r

r

u

c

l

a

n

r

e

t

x

e

f

o

e

u

l

a

v

d

a

e

R

6

0

u

A

m

l

a

n

g

i

s

e

g

a

t

l

o

v

l

a

n

r

e

t

x

e

f

o

e

u

l

a

v

d

a

e

R

7

0

u

V

n

e

e

b

s

a

h

e

l

u

d

o

m

n

o

i

t

a

c

i

n

u

m

m

o

c

a

t

a

d

a

f

i

e

l

b

i

s

s

o

p

e

b

y

l

n

o

ll

i

w

g

n

i

t

t

e

s

s

i

h

T

)

*

.

r

e

ll

o

r

t

n

o

c

e

h

t

n

i

d

e

ll

a

t

s

n

i

:

s

e

g

a

s

s

e

m

g

n

i

w

o

l

l

o

f

e

h

t

e

v

i

g

n

a

c

r

e

l

l

o

r

t

n

o

c

e

h

T

1

E

r

e

ll

o

r

t

n

o

c

e

h

t

n

i

s

r

o

r

r

E

1

1

E

e

g

n

a

r

s

t

i

e

d

i

s

t

u

o

e

r

u

t

a

r

e

p

m

e

t

r

o

t

a

u

t

c

a

s

e

v

l

a

V

2

1

E

e

g

n

a

r

s

t

i

e

d

i

s

t

u

o

l

a

n

g

i

s

t

u

p

n

I

Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut out the supply voltage to the controller
- Keep both buttons depressed at the same time as you reconnect the supply

voltage

Summary of Contents for EKC 366

Page 1: ...TEAQ CVMQ Instructions EKC 366 RI 8B G1 52 05 2000 Tilslutning Connection Anschlu Raccordement 0 10 V d c 15 16 eller or oder ou 2 10 V d c 15 16 eller or oder ou 4 20 mA 18 19 eller or oder ou 0 20...

Page 2: ...lingen Menuoversigt n o i t k n u F a r a P r e t e m n i M x a M e d e l l i b l a m r o n r u t a r e p m e t e l l e u t k a s n e l i t n e v e s l f A C e c n e r e f e r r u t a r e p m e t s i...

Page 3: ...tuatortemperatur som svarer til den nskede fordampningstemperatur tryk Indstil v rdien i regulatoren som n vnt under Indstille ventilens basis temperaturreference De to kurver er vist med ventilens fj...

Page 4: ...ons and find the parameter you want to change 3 Push both buttons simultaneously until the parameter value is shown 4 Push one of the buttons and select the new value 5 Push both buttons again to conc...

Page 5: ...tempera ture corresponding to the required evaporating tempera ture push Set the value in the controller as mentioned under Set the valve s basic temperature reference The two curves are shown with th...

Page 6: ...tigen und einen neuen Wert festlegen 5 Erneut beide Tasten bet tigen um den Einstellvorgang abzuschlie en Men bersicht n o i t k n u F a r a P r e t e m n i M x a M d l i b l a m r o N r u t a r e p m...

Page 7: ...k entsprechende Stellantriebtemperatur ermitteln Den Wert im Regler wie im Abschnitt Einstellung der Referenztemperatur des Ventils beschrieben einstellen Die beiden Kennlinien gelten f r die der Werk...

Page 8: ...leur du param tre 4 Appuyer sur l un des boutons pour choisir la nouvelle valeur 5 Appuyer nouveau sur les deux boutons en m me temps pour terminer le r glage Sommaire des menus n o i t c n o F a r a...

Page 9: ...ur qui correspond la temp rature pression d vaporation voulue R gler alors la valeur dans le r gulateur comme expliqu en R glage de la r f rence de base pour la temp rature Ces deux courbes sont montr...

Page 10: ...10 Instructions RI 8B G1 52 Danfoss 05 2000 EKC 366...

Reviews: