background image

Manual RS8EB102 © Danfoss 09-2005 

EKC 

319A

AD

AP

-K

OOL®

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products 

already on order provided that such alternations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respecitve companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

The Product contains electrical components 

And may not be disposed together with domestic waste.

Equipment must be separate collected with Electrical and Elec-

tronic waste. According to Local and currently valid legislation.

Summary of Contents for EKC 319A

Page 1: ...Temperature controller for limitation for the discharge gas temperature EKC 319A User Guide ADAP KOOL Refrigeration control systems...

Page 2: ...ion valve type AKV or a type AKVA for NH3 is used The capacity requirement is determined by the size of the valve If the compressor is provided with a connection for liquid injection a pulse solenoid...

Page 3: ...With setting 0 the alarm is also transmitted via the data communica tion With data communication the impor tance of the individual alarms can be defined Setting is carried out in the Alarm destinatio...

Page 4: ...o18 Service Service A number of controller values can be printed for use in a service situation Read discharge gas temperature u01 Temperature Read the temperature reference u02 Temperature ref Read...

Page 5: ...the buttons and select the new value 5 Push both buttons again to conclude the setting SW 1 1x Function Para meter Min Max Fac setting Normal display Read the measured discharge gas temperature C If...

Page 6: ...brations Enclosure IP 20 Weight 300 g Montage DIN Rail Display LED 3 digits Terminals max 2 5 mm2 multicore Approvals EU Low Voltage Directive and EMC demands re CE marking complied with LVD tested ac...

Page 7: ...e upload all the collected tempera ture values once a day Example of menu display Measurements are shown at one side and settings at the other You will also be able to see the parameter names of the f...

Page 8: ...t such alternations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the respecitve companies Danfoss and Danf...

Reviews: