Error messages:
Thermostat EFIT 540/550 has a built-in system that
constantly checks the heating system, the thermostat itself
and a possible network for any malfunctions.
If an error occurs, the display will fl
ash together with a
reading of the detected fault, which will be shown indicated
by the weekday numbers 1 to 7:
No:
Fault:
What to do:
7
Clock is not adjusted
Set the clock
4
The thermostat is
Let the thermostat cool
switched off because
for a period.
of overheating
Then enter basic setup to
leave fault mode
3 Confi gur
ed as a
One unit must be
Slave, but cannot
confi gur
ed as Master
fi nd any Master unit