Fastening
C
Caution
•
Use of non-recommended screws can cause damage to housing.
•
Excessive screw torque force can cause damage to housing. Maximum torque: 0.9 N m (8 in-lbs).
•
Reassembly with self-tapping screws can damage existing threads in housing.
•
Oversized panel cutouts can jeopardize product IP rating.
•
Ensure the vent is not covered. This excludes the RAM mount option.
Fastening hole depth
mm [in]
7.5 [0.3]
Fastening hole depth: 7.5 mm (0.3 in). Standard M4x0.7 screw may be used.
Maximum torque: 0.9 N m (8 in-lbs).
Pin assignments
12 pin DEUTSCH connector
Pin 1
Pin 6
Pin 12
Pin 7
DEUTSCH DTM06-12SA 12 pin
C1 pin
DM430E-0-x-x-x
DM430E-1-x-x-x
DM430E-2-x-x-x
1
Power ground -
Power ground -
Power ground -
2
Power
Power
Power
3
CAN 0 +
CAN 0 +
CAN 0 +
4
CAN 0 -
CAN 0 -
CAN 0 -
5
AnIn/CAN 0 Shield
AnIn/CAN 0 Shield
AnIn/CAN 0 Shield
6
DigIn/AnIn
DigIn/AnIn
DigIn/AnIn