DHP-M M and S
1
2
3
6
5
4
9
8
7
12
13
14
15
10
16
17
18
19
20
21
22
23
24
11
The arrows show input to and output from the heat pump.
1. Return pipe, heating system
2. Supply pipe, heating system
3. Hot gas to water heater
4. Returning hot gas from water heater
5. Brine out
6. Brine in
7. Lead-in for incoming supply
8. Lead-ins for communication cable and sensor
9. Control panel
10. Inverter
11. Flexible hose
12. Hot gas exchanger
13. Service output, high pressure
14. High pressure transmitter
15. High pressure switch
16. Condenser pump
17. Condenser
18. Drying filter
19. Brine pump
20. Low pressure transmitter
21. Service outlet, low pressure
22. Evaporator
23. Compressor
24. Electronic expansion valve
DHP-M M and S Connections, pipe diameter in mm
Brine
Heating system
Hot gas exchanger
42
35
28