More than one secondary heat pump
3
4
5
6
1
2
8
7
1
Router/Switch
2
Possibility of internet access via router
3
Primary (controlling) heat pump with IP address e.g.
192.168.000.100
4
Secondary heat pump with IP address e.g. 192.168.000.102
5
Secondary heat pump with IP address e.g. 192.168.000.103
6
Secondary heat pump with IP address e.g. 192.168.000.104
X
Secondary heat pump with IP address e.g. 192.168.000.XXX
7
Online Web server and database
8
Online web browser
The secondary heat pump must always point to the primary heat
pump IP address.
Menu settings
N
If more than one heat pump is installed, network settings must be en-
tered in every one of the units.
N
Contact your network administrator if settings in a router or other net-
work equipment is required.
1. Press
in the upper left corner of the Start screen.
2. Press
.
3. Press the text System settings
4. Press the text Network settings
For automatic IP-settings:
1. Set Dhcp/static to 0 (factory default)
2. Press to return to System settings.
Or press
in the upper left corner to return to the Menu screen.
For manual IP-settings:
1. Set Dhcp/static to 1
2. Press on each relevant figure in the IP-address and then on respectively + and – to change the setting.
3. Repeat previous step for Network mask, IP gateway etc.
4. Press
to confirm the setting.
5. Press to return to System settings.
Or press
in the upper left corner to return to the Menu screen.
Commissioning
DHP-M
Danfoss Heating Solutions
VIJSE302
21
Summary of Contents for DHP-M
Page 1: ...MAKING MODERN LIVING POSSIBLE Commissioning DHP M www heating danfoss com...
Page 36: ...Commissioning DHP M VIJSE302 Danfoss Heating Solutions 36...
Page 37: ...Commissioning DHP M Danfoss Heating Solutions VIJSE302 37...
Page 38: ...Commissioning DHP M VIJSE302 Danfoss Heating Solutions 38...
Page 39: ...Commissioning DHP M Danfoss Heating Solutions VIJSE302 39...