5.7
Heating Settings
In Heating settings, you can set seasonal stop, min/max supply line temperature and comfort factor.
The
Comfort factor
(0 - 3) influences the desired Supply line (HP) value. If the Comfort factor is set to for example 3, an increase of the of
the Comfort wheel setting with +1 will result in an increase of the supply line temperature with +3 ºC.
1. Press
on the Start screen to open the Menu screen.
2. Press
3. Press
if the Heat settings window is not shown.
4. Make the desired changes.
5. Confirm settings by pressing
Caution
Adjusting the minimum and maximum supply temperatures is particu-
larly important if your home has under floor heating.
If your house has under floor heating and heat sensitive floors, the supply line temperature must not exceed certain temperatures. Oth-
erwise the floor might get damaged.
5.8
Default Heating Settings
The control system has two different default settings available from factory:
▪
radiator system (factory default)
▪
underfloor heating
The default settings will affect the heat curve settings and minimum and maximum supply line temperature. Further adjustments may
be necessary also after setting default settings.
Important: If the system shall be configured to Underfloor heating or similar, it is a must to set the heat pumps default value to floor
heating. If this is not done, the "factory reset" button will reset the heat curve and max/min supply line temperatures to default values
for radiator systems, which may cause damages on systems with e.g. floor heating.
To change default heat settings from Radiator to Floor heating (or reverse):
1. Press
on the Start screen to open the Menu screen.
2. Press
3. Press
if the Heat curve window is not shown.
4. Press
for underfloor heating systems or
for radiator systems
5. Make the desired changes.
6. Press
to set the new "factory reset" value to the selected system.
7. Confirm settings by pressing
Commissioning
DHP-H Varius Pro+/DHP-L Varius Pro+
VIJSG202
Danfoss Heating Solutions
18