DEVIreg™ 330 (+60 °C to +160 °C)
Installation Guide
4
1.1
Technical Specifications
Operation voltage
220-240 V~, 50-60 Hz
Standby power consumption Max 0,25 W
Relay:
Resistive load
Inductive load
Max 16 A / 3680 W @ 230 V
cos φ= 0,3 max1A
Sensing units
NTC 16,7 kOhm at 100 °C
Sensing values:
25 °C
50 °C
100 °C
120 °C
170 °C
300 kOhm
99,4 kOhm
16,7 kOhm
8,8 kOhm
2,35 kOhm
Hysteresis
± 0,4 °C
Ambient temperature
10 °C to +50 °C
Temperature range
+60 °C to +160 °C
Cable specification max
1x4 mm
2
or 2x2,5 mm
2
Ball pressure temperature
75 °C
Pollution degree
2 (domestic use)
Type
1C
Storage temperature
-20 °C to +65 °C
Summary of Contents for DEVI 140F1073