background image

Danfoss Heating

3

Installation Instructions

Specifications

TPOne-S

DBR

Operating Voltage

230V AC, 50 Hz

Setting temperature range

5-35°C

 - 

Operating temprature range

0-45°C

Switch rating

3A (1) at 230Vac

Switch type

SPST Type 1A

Transmission frequency 

868.42 MHz

WiFi Specification 

802.11b/g (2.4GHz)

Transmission range (in 
normal buildings)

up to 30m

Transmission power 

Max 1 mW

IP rating

IP20

IP40

On/off control

Yes 

Chrono-proportional control

Yes

Operating mode

Heating

 - 

Construction

EN 60730-2-9

EN 60730-1

Control pollution situation

Degree 2

Rated impulse voltage

 2.5kV

Ball pressure test

75°C

Dimensions (mm)

H66 x W155 x D30

H84 x W84 x D30

Software Classification

A

Important note RF products: Ensure that there are no large metal objects, 
such as boiler cases or other large appliances, in line of sight between the 
transmitter and receiver as these will prevent communication between 
thermostat and receiver.

Summary of Contents for DBR

Page 1: ...Danfoss Heating TPOne S Electronic Programmable Room Thermostat Installation Guide...

Page 2: ...oduct Function and ErP Description Additional efficiency gain V Modulating Room Thermostat for use with modulating heaters An electronic room thermostat that varies the flow temperature of the water l...

Page 3: ...ion power Max 1 mW IP rating IP20 IP40 On off control Yes Chrono proportional control Yes Operating mode Heating Construction EN 60730 2 9 EN 60730 1 Control pollution situation Degree 2 Rated impulse...

Page 4: ...e leaving a minimum distance of 30cm away from any metal enclosures or appliance and positioned so that no large metal obstruction is between the receiver and thermostat The thermostat can be mounted...

Page 5: ...Danfoss Heating 5 TPOne S wiring Wiring DBR Receiver DBR Receiver 1 N L 2 3 4 230 Vac COM OUT Not Used N L 230 Vac Note When using the table stand ONLY USE the power supply and USB cable provided...

Page 6: ...r schedule to the way you live The Home Away and Asleep comfort modes are linked to your defined comfort temperatures The schedule follows the daily routine you have set or you just choose the comfort...

Page 7: ...The required temperature for Away mode is selectable in the Temperature setting see User Menu Temperatures Asleep Asleep Mode selects the nightime comfort temperature which is set between the end of...

Page 8: ...OK will be shown on the display when it can be used or is required Menu Back Press O to exit a menu option Pressing O while in a setting will result in that setting change not be accepted O will also...

Page 9: ...set schedule This is indicated by the Hot Water Calling icon The TPOne S is connected by radio signal to a receiver The Radio Frequency icon will be displayed to confirm that this connection is activ...

Page 10: ...e further changes can be made in the user and installer setting menus OK RF Pairing RF Pairing Language English OK Set Date 04 02 2016 OK Set Time 24hr 10 45 OK OK OK OK OK OK OK OK OK READY OK DBR Re...

Page 11: ...Temperatures AM 21 0 o OK 21 5 o 10 45 Thurs User Menu Temperatures OK OK OK OK OK OK OK OK 21 0 o Follow this routine to set required Comfort Mode temperatures Changes can be made for each mode once...

Page 12: ...ule Days can be set individually or grouped and options for weekdays and weekend settings can be selected All day combinations can then have one two or three Home Periods selected TPOne will automatic...

Page 13: ...hedule Heating User Menu Mon Tues Weds Thurs Fri Sat Sun OK OK OK OK From To 06 00 08 30 OK OK OK Home Period 2 OK From To 12 30 13 30 OK OK OK Home Period 3 OK From To 17 30 22 30 OK OK OK OK OK Sele...

Page 14: ...14 TPOne S TPOne Programme via App TPOne can be programmed via a smartphone App Download the App from App Store or Google Play by following the QR code or by searching for TPOne...

Page 15: ...rom the TPOne S App to pair your TPOne S User Settings WiFi Setup WiFi Setup WiFi Setup OK Press OK to setup WiFi connection 21 5 o 10 45 Thurs OK OK Open TPOne Heating App on mobile device and follow...

Page 16: ...heating only this menu option will not be given The hot water heating feature can be deactivated after installation see User Menu Installer Settings Hot Water Setup Click Save Click Save is an easy ac...

Page 17: ...this guide Tempertures User set comfort temperatures heating individual comfort temperatures for Home AM Home PM Away and Asleep Home AM and Home PM temperatures will be set during the home periods c...

Page 18: ...press Button Click can be switched On or Off Default setting On Backlight When buttons are pressed on the TPOne the display backlight will come on to aid viewing Where backlight is not required this...

Page 19: ...domestic hot water are only accessable if the Hot Water Setup is switched on TPOne S controls only the time schedule for domestic hot water and should always be used with a suitable hot water cylinde...

Page 20: ...me the time at which you would like to be up to the required temperature The thermostat then calculates how soon before the required time the heating is turned up Optimised Start in TPOne is dynamic a...

Page 21: ...installer can set the service due date and select from one of four service due restriction modes 1 Warning Only visual and audible warnings only no reduction of heat 2 Heat 45min hr visual and audibl...

Page 22: ...will be required to make any installer setting changes Installer Reset Select option to reset all installer settings to factory defaults Note Service interval will not be reset and can only be reset o...

Page 23: ...cancelled the alarm will recommence the following day at noon If the boiler is not serviced before the due date an audible warning will start each day at noon the service icon will also be displayed...

Page 24: ...30 22 30 06 30 08 30 Weekend 07 30 09 30 11 30 13 30 16 30 22 30 1 2 3 Note Where TPOne has been set up for domestic hot water control the default schedule for hot water is the same as for heating In...

Page 25: ...Danfoss Heating 25 AM 20 C PM 20 C 15 C 15 C TEMPERTURE DEFAULTS Default tables Continued...

Page 26: ...the warning has been corrected then the message can be cancelled by selecting Clear Warnings in the TPOne menu Where more than one warning has occurred the most recent will be shown on the display All...

Page 27: ...ting system should be checked to confirm it is operating correctly Low Heat If set mode temperature is not reached within 2 hours then TPOne will warn of Low Heat The heating system should be checked...

Page 28: ...these may prevent connection No IP Address If the TPOne S is connected to the home router but it is unable to obtain a valid IP address this warning will be shown No Internet Found If the TPOne S has...

Page 29: ...receiver will need to be installed for domestic hot water control OK Hot Water RF Pairing User Menu Installer Settings OK Installer Settings RF Pairing OK OK OK OK OK READY OK DBR Receiver 21 5 o 10 4...

Page 30: ...to install Updates to use the Product for remote access 3 Consent to use of data By installing and using the Application you give your consent and agree that Danfoss may collect use register and store...

Page 31: ...s sole risk The Software and results and information generated thereby cannot substitute technical advice but must be verified by the User they are not promises and should not be relied on as accurat...

Page 32: ...Danfoss Ltd Ampthill Road Bedford MK42 9ER Tel 01234 364621 Fax 01234 219705 Email ukheating danfoss com Website www heating danfoss co uk Danfoss HS 01 2018 VIHSK102...

Reviews: