D
GB
F
E
© Danfoss | Climate Solutions | 2023.06
AQ452531257528en-000201 | 7
1
2
3
4
5
13
12
7
11
6
10
8
9
HRX40-2
24A
7,3
8,7
2
|
Product description
Fig. 3
2.2 Name plate
(example)
HR
40- 2 CO
2
X
¹
)
HR - Hermetic Radial Gas-Cooled (suction gas-cooled
)
²
)
X - Ester oil charge
³
)
H - Horizontal
Engineering design ³
)
Transcritical
CO
2
version
Number of poles
Swept volume
Oil charge ²
)
Series ¹
)
T H
2.3 Type key
(example)
160,0A
1 Type designation
2 Machine number
3 Maximum operating current (mains operation)
4 Starting current (rotor blocked)
5 ND (LP): max. permissible operating
pressure (g) Low pressure side
HD (HP): max. permissible operating
pressure (g) High pressure side
Observe the limits of
application diagrams!
50 Hz
60 Hz
6 Voltage, circuit, frequency
7 Nominal rotation speed
8 Displacement
9 Voltage, circuit, frequency
10 Nominal rotation speed
11 Displacement
12 Oil type filled at the factory
13 Terminal box protection type
Electrical accessories can change
the IP protection class!
}
}
BOCK
Bock GmbH, Benzstr. 7
72636 Frickenhausen, Germany
BOCK
lub E85