22 | 180R9346 | AQ240486503020en-001702
© Danfoss | 2023.03
Operation guide
Installation, Operation and Maintenance APP 53-92 pumps
4.1 APP 53-92
4
Technical data
Pump size
APP 53/1500 APP 65/1500
APP78 /1500
APP 86/1700
APP 92/1780
Code number
180B7806
180B7807
180B7808
180B7809
180B7810
Geometric
displacement
cm³/rev.
617
778
888
888
888
in³/rev.
37.7
47.3
54.2
54.2
54.2
Pressure
Max. outlet
1)
pressure
(MAWP)
barg
83
83
83
70
70
psig
1,200
1,200
1,200
1,015
1,015
Min. inlet
operating
pressure
barg
2
2
2
2.5
3.5
psig
29
29
29
36
50
Max. inlet
operating
pressure
barg
5
5
5
5
5
psig
73
73
73
73
73
Max. inlet
pressure peak
barg
10
10
10
10
10
psig
145
145
145
145
145
Min. outlet
pressure
barg
30
30
30
30
30
psig
435
435
435
435
435
Speed
Min. speed
continuous
rpm
700
700
700
700
700
Max. speed
continuous
rpm
1,500
1,500
1,500
1,700
1,780
Flow
Min. flow
m³/h
24
32
36
36
36
gpm
106
141
158
158
158
700 rpm at
max. pressure
m³/h
24
32
36
36
36
gpm
106
141
158
158
158
1000 rpm at
max. pressure
m³/h
35
45
52
52
52
gpm
154
198
228
228
228
1200 rpm at
max. pressure
m³/h
42
54
62
62
62
gpm
187
238
275
275
275
1500 rpm at
max. pressure
m³/h
53
68
78
78
78
gpm
235
299
345
345
345
1700 rpm at
max. pressure
m³/h
88
88
gpm
387
387
1780 rpm at
max. pressure
m³/h
92
gpm
405
Efficiency
1000 rpm
3)
%
88
88
89
89
89
1200 rpm
3)
%
89
89
90
89
89
1500 rpm
3)
%
88
89
89
88
88
1700 rpm
3)
%
88
88
1780 rpm
3)
%
87