Service and warranty
Danfoss APP S 674 pumps are designed for long
operation, low maintenance and reduced
lifecycle costs.
Provided that the pump has been running
according to the Danfoss specifications, Danfoss
guarantees 8,000 hours service-free operation,
however, max 18 months from date of produc-
tion.
If Danfoss recommendations concerning
system-design are not followed,
it will strongly
influence the life of the APP S 674 pumps
.
Maintenance:
After 8,000 hours of operation, it is strongly
recommended to inspect the pump and change
any worn parts, e.g. pistons. This is done in order
to prevent a potential breakdown of the pump.
If the parts are not replaced, more frequent
inspection is recommended according to our
service intervals.
Standstill:
The APP S 674 pumps are made of Super Duplex
materials with excellent corrosion properties.
It is always recommended to flush the pump
with freshwater when the system is shut down.
9.1 Repair
In case of irregular function of the APP S 674
pump, please contact Danfoss High Pressure
Pumps.