22
180R9270 / IOM APP S 674 - v01 / 03.2013
Data sheet
APP S 674 pumps
4
521B1187 / DKCFN.PD.014.H2.02 / 03.2013
Pumps size
APP S 674 3.0
APP S 674 3.5
Code number
On request
On request
Geometric displacement
cm³/rpm
17.7
20.5
in³/rpm
1.08
1.25
Pressure
Outlet min. pressure,
continuous
1)
barg
20
20
psig
290
290
Outlet max. pressure,
MAWP
barg
80
80
psig
1160
1160
Inlet operating pressure
2)
barg
0.5-10
0.5-10
psig
7.25-145
7.25-145
Inlet design pressure
barg
15
15
psig
217
217
Speed
Min. speed, continuous
rpm
700
700
Max. speed, continuous
3)
rpm
3000
3000
Typical Flow
1500 rpm at max pressure
m
3
/h
1.5
1.75
3000 rpm at max pressure
m
3
/h
3.0
3.5
1800 rpm at max pressure
gpm
7.9
9.3
3000 rpm at max pressure
gpm
13.3
15.4
Typical motor size
1500 rpm at max pressure
kW
4.0
5.5
1800 rpm at max pressure
hp
7.5
7.5
Torque at max outlet
pressure
Nm
25.6
29.7
lbf-ft
18.9
21.9
Media temperatur
4)
°C
2-50
2-50
°F
36-122
36-122
Ambient temperatur
°C
0-50
0-50
°F
32-122
32-122
Weight
kg
15
15
lb
33
33
1)
For lower pressure, please contact Danfoss High Pressure Pumps
2)
If inlet pressure exceeds inlet operating pressure, Danfoss recommends
inspection of the pump and shaft seal
3)
For higher speed, please contact Danfoss High Pressure Pumps
4)
Dependent on the NaCl concentration
4.
Technical data
4.1 APP S 674 3.0-3.5