background image

4 | © Danfoss | 2017.07

VI.KU.L5.9O 

AMV 130(H), AMV 140(H)

ENGLISH

Safety Notes

To avoid injury of persons and 
damages to the device, it is absolutely 
necessary to read and observe these 

instructions carefully.

Necessary assembly, start-up, and maintenance 
work must be performed by qualified and 
authorized personnel only.

Please comply with the instructions of the 
system manufacturer or system operator.

Do not remove the cover before the 
power supply is fully switched off.

Disposal instruction

This product should be dismantled 
and its components sorted, if possible, 
in various groups before recycling or 
disposal. 

Always follow the local disposal regulations.

Mounting 

In case of ship applications (on water) actuator 
should be mounted with the valve stem in 
either 30° above horizontal position or pointing 
upwards. 
In case of building applications actuator should 
be mounted with the valve stem in either 
horizontal position or pointing upwards.The 
actuator is fixed to the valve body by means 
of a ribbed nut which requires no tools for 
mounting. The ribbed nut should be tightened 
by hand.

Wiring 

24 V

Grey

Stem down

Black

Common

Red

Stem up

230 V

Black

Stem down

Blue

Common

Brown

Stem up

Do not touch anything on the PCB! 
Lethal voltage!

Installation 

1.  Check the valve neck. The actuator should 

be in steam up position (factory setting). 
Ensure that the actuator is mounted securely 
on the valve body

2.  Wire the actuator according to the wiring 

diagram

3.  The direction of stem movement can be 

observed on the position indicator 

Manual override

(for service purposes only)

Do not manually operate the drive if 
power is connected!

AMV 130, AMV 140 

  Remove cover

  Insert the Allen key 6 into the spindle

  Press and hold the button (on the bottom 

side of the actuator) during manual override

  Pull out the tool

  Replace cover

 

Remark

: A ‘click’ sound after energising the 

actuator means that the gear wheel has 
jumped into normal position.

AMV 130H, AMV 140H 

Press and hold the button 

 (on the bottom 

side of the actuator) during manual override.

 

Remark

: A ‘click’ sound after energising the 

actuator means that the gear wheel has 
jumped into normal position.

Dimensions 

Part Name 

部件名称

Hazardous Substances Table/

有害物质含量表

Lead (Pb) 

 (Pb)

Mercury (Hg) 

 (Hg)

Cadmium (Cd) 

 (Cd)

Hexavalent Chromium (Cr(VI)) 

六价铬

 (Cr(VI))

Polybrominated biphenyls (PBB) 

多溴联苯

 (PBB)

Polybrominated diphenyl ethers (PBDE) 

多溴二苯醚

 (PBDE)

Connecting nut

X

O

O

O

O

O

连接螺母

X

O

O

O

O

O

O:  Indicates that this hazardous substance contained in all of the homogeneous material for this part is below the limit requirement in GB/T 26572; 
O:  

表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572规定的限量要求以下。

X:  Indicates that this hazardous substance contained in at least one of the homogeneous material for this part is above the limit requirementw in GB/T 26572; 
X:  

表示该有害物质至少在该部件的某一均质材料中的含量超出

GB/T 26572

规定的限量要求。

Summary of Contents for AMV 130

Page 1: ...130 AMV 140 AMV 130H AMV 140H www danfoss com Page 6 MAGYAR Szelepmozgat k h rompontos szab lyoz shoz AMV 130 AMV 140 AMV 130H AMV 140H www danfoss com Page 7 ESKY Servopohony s t bodov m regula n m...

Page 2: ...2 Danfoss 2017 07 VI KU L5 9O AMV 130 H AMV 140 H AMV 130 140 5 95 RH no condensing MAINTENANCE FREE 4 6mm 1mm 6 mm 6 mm AMV 130 140 AMV 130H 140H 24V AMV 130 140 AMV 130H 140H 230V 3 0 3 0...

Page 3: ...g 92 L H h 1 d AMV130 140 VZL stem extension plug Valve type d L H H1 h1 mm VZL 2 DN 15 G 65 111 117 29 5 VZL 2 DN 20 G 77 117 123 34 0 VZL 3 DN 15 G 65 111 117 35 0 VZL 3 DN 20 G 77 117 123 35 0 VZL...

Page 4: ...lve neck The actuator should be in steam up position factory setting Ensure that the actuator is mounted securely on the valve body 2 Wire the actuator according to the wiring diagram 3 The direction...

Page 5: ...Wartungsarbeiten d rfen nur von sachkundigen und autorisierten Personen durchgef hrt werden Die Vorgaben des Anlagenherstellers und Anlagenbetreibers sind zu beachten Abdeckungerstentfernen wenndie S...

Page 6: ...140H Houd de knop aan de onderzijde van de servomotor ingedrukt gedurende het verdraaien van de handbediening aan de bovenzijde van de servomotor Opmerking Wanneer de servomotor weer onder spanning w...

Page 7: ...helyzet t A szelepmozgat t felfel mutat szelepsz rra kell felszerelni gy ri be ll t s Bizonyosodjon meg a szelepmozgat szeleptestre t rt n biztons gos r gz t s r l 2 K sse be a szelepmozgat t a huzalo...

Page 8: ...ap ytce drukowanej Napi cieniebezpieczne dla ycia Monta 1 Sprawdzi szyjk zaworu Si ownik powinien by w pozycji podniesionego trzpienia zaworu ustawienie fabryczne Upewni si e si ownik zosta zamontowan...

Page 9: ...ar rievotu uzgriezni kuram nav nepiecie ami citi instrumenti Rievotais uzgrieznis ir j pievelk ar roku Elektroinstal cija 24 V Pel ks K ts uz leju Melns Kop js Sarkans K ts uz aug u 230 V Melns K ts u...

Page 10: ...10 Danfoss 2017 07 VI KU L5 9O AMV 130 H AMV 140 H...

Page 11: ...Danfoss 2017 07 11 VI KU L5 9O AMV 130 H AMV 140 H...

Page 12: ...es the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed Al...

Reviews: