Manual RS8FB102 © Danfoss 03-2008 

AK-PI 

100

DE-DB

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alternations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respecitve companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Ordering

Accessories

Accessories Transformer module 230 V / 115 V to 24 V

AK-PS 075

18 VA

Supply 

080Z0053

-

RS 232 cable between AK-PI 100 and Woodley MDM / 4 way TPI card 

080Z0263

Type

Function

Application

Language

Code no.

AK-PI 100

Protokol interface

Intermediary link between System controller AK-SC 255 and 

Woodley controllers.  The unit makes is possible to change the 

user interface from Woodley's S5 to Danfoss' AK-SC 255

English, French,

080Z8522

Data

Supply voltage

24 V AC. +/- 20%

Power consumption

AK-PI 100

8 VA

Ambient environment

During transport

-40 to 70°C

During operation

-20 to 55°C ,

0 to 95% RH (non condensing)

No shock influences / vibrations

Enclosure

Material

PC / ABS

Protection

IP10 , VBG 4

Installation

Built in. On panel wall or DIN rail

Weight

Ca. 600 g

Approvals

EU low voltage directive and EMC require-

ments are complied with

LVD tested to EN 60730

EMC tested

Immunity to: EN 61000-6-2

Emission to: EN 61000-6-3

Summary of Contents for AK-PI 100

Page 1: ...Woodley Protokol interface AK PI 100 User Guide ADAP KOOL Refrigeration control systems...

Page 2: ...orward connection the two units can be linked by a switch In this case the IP addresses are set to static addresses You can choose any addresses but only if nothing else is connected It is easiest to...

Page 3: ...200 screen Each PI unit is configured with a different address You can choose 11 12 or above e g 21 Addresses 1 to 10 are reserved for sub nets Connection When you configure the system controller the...

Page 4: ...d In the AK PI 100 set IP addressing to either static or dynamic Choose static if the AK SC 255 and AK PI 100 are linked by a switch Then configure the IP address request an IP address from the IT of...

Page 5: ...ith Communications I O Network Rescan channels Select the Channel PI 100 200 field Activate the Rescan Network function Click the PI 100 200 button to switch to the next screen Select the addresses to...

Page 6: ...rols Specify the description file Select No for Pack controller Select the number of controllers in this example 10 Click the Setup button to switch to the next screen Click Edit on the first controll...

Page 7: ...ss to the following The configuration lock is used with the following settings Communication setting MDM or WTP Address offset setting addresses are configured for all units on the communication line...

Page 8: ...VA Supply 080Z0053 RS 232 cable between AK PI 100 and Woodley MDM 4 way TPI card 080Z0263 Type Function Application Language Code no AK PI 100 Protokol interface Intermediary link between System cont...

Reviews: