P108790
QC125
* Included in overhaul seal kit Q210
C155
QC150
QC120
C154
C149
C151
C152
H020
C153
*C200
C300
Item
Description
Wrench size
Torque
C149
Orifice
3 mm internal hex
2.7 Nm [24 in-lb]
C151
Screws
6.4 Nm [4.7 lbf-ft]
C152
Manifold
-
-
C153
Plug
5 mm internal hex
12 Nm [8.9 lbf-ft]
C154
O-ring
-
-
C155
Solenoid
-
-
C200
O-rings
-
-
C300
Screws
6.4 Nm [4.7 lbf-ft]
QC120
O-rings
QC125
Nut
8.7 Nm [6.4 lbf-ft]
QC150
Valve assembly
27.7 Nm [20.4 lbf-ft]
H020
Manifold orifice
3 mm internal hex
2.7 Nm [24 in-lb}
Fan Drive Control
Disassembly
Use the wrench sizes and torques listed in the table.
1. Remove four screws (C300).
2. Remove the control and discard the 4 interface O-rings (C200).
3. Remove the coil plastic nut (QC125 ) Remove the coil.
Remember the correct coil connector orientation.
4. Remove the solenoid cartridge (C120). Remove O-ring (QC120).
5. Remove spring (C124) and spring guide (C123).
6. Remove the pressure limiter adjuster (C128).
7. Remove spring (C125) and spool (C122).
8. Remove plug (C107) and plug (C129).
9. Remove gain orifice (H030).
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Disassembly
16 |
©
Danfoss | April 2017
AX00000305en-US0101