10 Specifications
10.1 Power-dependent Specifications
Mains supply 200-240 V AC - Normal overload 110% for 1 minute
Frequency converter
Typical Shaft Output [kW]
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3
P3K7
3.7
IP20/Chassis
(A2+A3 may be converted to IP21 using a conversion kit. (See also
Mechanical mounting
and
IP21/Type 1 Enclosure kit
in the Design
Guide.))
A2
A2
A2
A3
A3
IP55/Type 12
A4/A5
A4/A5
A4/A5
A5
A5
IP66/NEMA 4X
A4/A5
A4/A5
A4/A5
A5
A5
Typical Shaft Output [HP] at 208 V
1.5
2.0
2.9
4.0
4.9
Output current
Continuous (3 x 200-240 V) [A]
6.6
7.5
10.6
12.5
16.7
Intermittent (3 x 200-240 V) [A]
7.3
8.3
11.7
13.8
18.4
Continuous kVA (208 V AC) [kVA]
2.38
2.70
3.82
4.50
6.00
Max. input current
Continuous (3 x 200-240 V) [A]
5.9
6.8
9.5
11.3
15.0
Intermittent (3 x 200-240 V) [A]
6.5
7.5
10.5
12.4
16.5
Additional specifications
Estimated power loss at rated max. load [W]
4)
63
82
116
155
185
IP20, IP21 max. cable cross section (mains, motor, brake and load
sharing) [mm
2
(AWG)]
4, 4, 4 (12, 12, 12)
(min. 0.2 (24))
IP55, IP66 max. cable cross section (mains, motor, brake and load
sharing) [mm
2
(AWG)]
4, 4, 4 (12, 12, 12)
Max. cable cross section with disconnect
6, 4, 4 (10, 12, 12)
Weight enclosure IP20 [kg]
4.9
4.9
4.9
6.6
6.6
Weight enclosure IP21 [kg]
5.5
5.5
5.5
7.5
7.5
Weight enclosure IP55 [kg] (A4/A5)
9.7/13.5
9.7/13.5
9.7/13.5
13.5
13.5
Weight enclosure IP66 [kg] (A4/A5)
9.7/13.5
9.7/13.5
9.7/13.5
13.5
13.5
Efficiency
3)
0.96
0.96
0.96
0.96
0.96
Table 10.1 Mains Supply 200-240 V AC
Specifications
VLT
®
HVAC Drive Operating Instructions
66
MG11AI02 - VLT
®
is a registered Danfoss trademark
10
10
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]