Danfoss Heating Solutions
VIUHM602
© Danfoss 03/2011
10
5.3 Setup
Menu
Setup:
From the start-up screen, activate the
Setup
menu to get access to a
variety of information and setting possibilities for Remote Controller as well as the entire
CF2
+
system. As some of the setting possibilities in the Setup menu can affect the con-
figuration of the CF2
+
system, and thus also the functionality of the entire application in
general, they should be handled with caution.
• Languages:
Choose another language than the one selected during the installation
process (see chapter 2).
• Date and time:
Provides access to setting of the date and time. Furthermore, this menu
includes settings for and activation of the summertime program. This enables you to
configure at what day, week and month the summertime begins and ends.
• Alarm:
Switch the alarm buzzer of CF-MC Master Controller On/Off. The buzz only oc-
curs in case of an alarm, also indicated by the red alarm LED on Master Controller (see
fig. 3-
). The
Alarm log
provides specific information about the error causing the alarm
and the time for its registration by the system. This
Alarm log
saves the latest alarms for
later access and easy system failure identification.
• Start-up screen:
Choose which room temperature shall be displayed on the start-up
screen.
• Service:
Configure all the outputs of Master Controller for either a floor or radiator heat-
ing system (regulation according to PWM (Pulse Width Modulation) principle). A mixed
system with floor and radiator heating in separate rooms can be selected by setting
the outputs of Master Controller individually for each room to either floor or radiator
heating (see chapter 6).
• Contrast:
Adjust the contrast of Remote Controller display.
• Link test:
Activate a test of the wireless transmission between Master Controller and
Remote Controller (see chapter 3).
• Identify Master Controller:
Identify a specific Master Controller in a system of up to
three Master Controllers. When this function is activated, the Master Controller, you
wish to identify, will flash all the output LEDs from 1 to 10 and back again several times
for easy identification
(option only available for systems with more Master Controllers).
Instruction
CF-RC Remote Controller