Software
Sirius digital Mixer from D&R Phone +31 294 418014, email:
Page 32
Conference TB
Conference talk-back shall be activated, including the module where this
input is routed to shall be switched to the CUE buss.
The output remotes can be continuously switching or momentary (pulse). In the pulse mode you
can decide to have this pulse during the ON action or during the OFF action or during both
switching actions.
The following functions can be carried out by the remotes:
On switch
indicates status of the switch.
Fader On
indicates status of the fader (open or closed).
Fader On & On
indicates status of the module (active or non-active).
CUE
indicates status of the CUE switch.
Red-light 1
indicated status of the red-light buss 1.
Red-light 2
indicates status of the red-light buss 2.
7.2.5 Input active generates:
When an input is active (fader up and On active) several activities can be programmed to be
carried out. Functions such as:
Red-light 1
when the module is active red-light 1 buss is activated.
Red-light 2
when the module is active red-light 2 buss is activated
Timer
when the module is active the Timer (buss) is activated.
Control room mute
when the module is active the CRM mute buss is activated. In this way
CRM speakers can be muted (Note: only when you have programmed
the output mutes to be controlled by the CRM mute buss)
Studio 1 mute
when the module is active Studio 1 mute buss is activated. In this way
Studio-1 speakers can be muted (Note: only when you have programmed
the output mutes to be controlled by the Studio 1 mute buss)
Studio 2 mute
when the module is active Studio 2 mute buss is activated. In this way
Studio 1 speakers can be muted (Note: only when you have programmed
the output mutes to be controlled by the Studio 2 mute buss).
Local CUE reset
when the module is active the CUE (when On) of the related channel
shall be switched off when necessary.
Total CUE reset
when the module is active, the CUE off all channels shall be switched off,
so the CRM can monitor the broadcast directly.