120 V AC / 60 Hz / 0.2 Ω Source impedance
Mode/Level
Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
POWER switch off
–
0.09
0.07
1
0
1
3
1
Standby
–
0.17
0.44
9
0
9
31
8
On, idling
–
1.57
0.89
168
0
168
573
144
Signal CF 12 dB cont.
4 Ω/Ch.
25.50
0.98
3000
2150
850
2900
731
Signal CF 9 dB cont.
4 Ω/Ch.
30.00
0.98
3600
2600
1000
3412
860
Signal CF 9 dB max.
4 Ω/Ch.
54.00
0.99
6400
4000
2400
–
–
100 V AC / 60 Hz / 0.2 Ω Source impedance
Mode/Level
Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
POWER switch off
–
0.08
0.07
1
0
1
2
0
Standby
–
0.17
0.50
9
0
9
31
8
On, idling
–
1.82
0.91
163
0
163
556
140
Signal CF 12 dB cont.
4 Ω/Ch.
32.50
0.99
3250
2150
1100
3753
946
Signal CF 9 dB cont.
4 Ω/Ch.
29.00
0.99
2900
2000
900
3071
774
Signal CF 9 dB max.
4 Ω/Ch.
55.00
0.99
5500
3500
2000
–
–
d&b D80 Manual 1.8 en
69
Summary of Contents for D80
Page 1: ...D D80 Manual 1 8 en ...
Page 32: ...Device setup access chart Hierarchy level 9 Device setup d b D80 Manual 1 8 en 32 ...
Page 50: ...Channel setup access chart Hierarchy level 10 Channel setup d b D80 Manual 1 8 en 50 ...
Page 79: ......