12.1. Power supply
The device utilizes a switch mode power supply with active Power
Factor Correction (PFC) and automatic mains range selection.
The power supply is equipped with mains voltage monitoring,
overvoltage and undervoltage protection as well as an inrush
current limiter.
12.1.1. Active Power Factor Correction (PFC)
The active
Power Factor Correction provides a clean and highly
efficient sinusoidal current draw, thus providing highest
performance under adverse mains conditions or when very long
power cabling is necessary.
The power factor is above 0.9 for mains power consumption
values of 500 W or higher.
12.1.2. Automatic mains range selection
The automatic mains range selection enables the device to be used
with any mains supply worldwide without the need for manual
action.
High range
208 - 240 V AC
Low range
100 - 127 V AC
Nominal mains ranges
Behavior with fluctuating mains voltages
With mains voltages other than the nominal voltages specified
above, the device switches to the adequate mode for either
'Protection' or 'Operation'.
The voltage thresholds are dependent on the slope of the mains
voltage change.
Undervoltage
Undefined
Overvoltage
The Main Power Supply is switched off. In
undervoltage state, the auxiliary mains
supply for device control only operates to a
limited extend.
0
Ü
75
Ü
133
Ü
170
Ü
266
Ü
400
Undervoltage
Low range
Undefined
High range
Overvoltage
Protection
Operation
Protection
Operation
Protection
0
Þ
85
Þ
140
Þ
190
Þ
276
Þ
400
12.1.3. Mains voltage monitoring
The mains voltage and frequency are recorded by the power
supply and can be viewed on screen. Where voltages outside of
this range are present, a self-resetting protective circuit responds
quickly to isolate the internal Main Power Supply leaving only a
supervisory circuit running to monitor the mains voltage. The device
accepts mains voltages of up to 400 V AC
RMS
without damage to
the device in case of a missing neutral line or running phase to
phase.
12. Operation (Hardware references)
d&b D80 Manual 1.8 en
65
Summary of Contents for D80
Page 1: ...D D80 Manual 1 8 en ...
Page 32: ...Device setup access chart Hierarchy level 9 Device setup d b D80 Manual 1 8 en 32 ...
Page 50: ...Channel setup access chart Hierarchy level 10 Channel setup d b D80 Manual 1 8 en 50 ...
Page 79: ......
Page 80: ...D2020 EN 01 03 2015 d b audiotechnik GmbH www dbaudio com ...