background image

KEY PAD FUNCTIONS

POWER SWITCH:

Turns unit ON/OFF

MODE:

Allows you to scroll through and select

desired operating mode. 

FAN:

Select from three different fan settings; 

High,

Medium, and Low.

AUTO-TIMER

AUTO-TIMER Adjust: 

Auto off-

With machine in 

running mode

, press timer

button to set timer control. Press 

or 

buttons to

select number of hours you would like the unit to run

before it automatically shuts off. 

Auto on-

With machine in 

stand by mode

, press timer

button to set timer control. Press 

or 

buttons to

select number of hours before the unit automatically

starts running 

in air conditionning mode

NOTE: The time is adjustable between 1-24 hours. 

TEMPERATURE Adjust:

• Used for adjusting the thermostat.

• The default display is room temperature.

• In cooling mode, when

button is pressed, the

set temperature is displayed and may be adjusted. After

15 seconds the display will revert back to room 

temperature. Temperature is only adjustable in cool mode.

Timer & Temp. Display 

Room Temp.

Temp. Set

Timer Set

MODE INDICATOR LIGHTS
Cooling Mode

When cool mode is selected, the indicator light

will shine

GREEN

. During the cooling mode, the

air is cooled and hot air is exhausted outside

through the exhaust tube. Adjust fan speed to suit

your desired comfort level.

Note:

The air exchange h ose must vent outside

the room when using cool mode.

Dehumidify Mode

When dehumidify mode is selected, the indicator

light will shine 

ORANGE

. Air is 

dehumidified as it passes through the unit, 

without being in full cooling mode. The fan will

operate on med. speed. If room temperature is

>25°C (77°F), fan speed can be adjusted; 

otherwise fan speed is fixed to “low”. 

Note:

The warm air exchange hose must vent

inside the room when using Dehumidify Mode,

not outside as it does when cooling. If the unit is

vented outside, some cooling will occur. 

Fan Mode

When fan mode is selected, the indicator will

shine 

YELLOW. 

Air is circulated throughout the

room with no cooling.

Note:

The unit does not need to be vented in Fan

mode. 

Heating Mode

When heating mode is selected the indicator will

shine 

RED

. Heating is activated only when the

ambient temperature is below 25°C (77°F). 

FAN SPEED INDICATOR LIGHTS

High Fan

Medium Fan

Low Fan

NOTE: By pressing both 

buttons at the

same time for more than 3 seconds, the display will

toggle between Celsius and Fahrenheit. 

STATUS DISPLAY

Warning Light

Condensed water may accumulate in the unit. If the 

internal tank becomes full, the Warning signal in the LCD

Display will light up and the unit will not operate until the

unit has been drained.

NOTE: After switching the air conditioner off, you must wait 3 minutes before switching it back on again.

5

OPERATION

FEATURES OF

THE CONTROL

PANEL

Summary of Contents for Premiere DPAC12010H

Page 1: ...ion Important Safety Information Installation Operation Care and Maintenance Troubleshooting Warranty CLIMATISEUR PORTATIF Guide d utilisation et soin de Propriètaire 11 20 Bienvenue Indentification de Partie Consignes de Sécurité Important Installation Fonctionnement Soins et Entretien Garantie KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE If the unit changes ownership be sure this manual accompan...

Page 2: ...g air processing appliance designed to offer you the functions of Air Conditioning Dehumidifying and Independent Fan Each individual mode is featured with oscillating air swing capabilities This unit can be conveniently moved from room to room within your home and set up in just minutes Imagine the convenience of 4 Season Home Comfort at your fingertips anywhere anytime For easy reference may we s...

Page 3: ...e representative if in doubt that the appliance is properly grounded 4 DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT If it is necessary to use an extension cord with this unit use an approved air conditioner extension cord only available at most local hardware stores 5 To avoid the possibility of personal injury always disconnect the power supply to the unit before installing and or s...

Page 4: ...ir conditioner off and use the FAN MODE on High Medium or Low This circulates indoor air providing some cooling comfort while utilizing less electricity NOTE The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire In the event the power supply cord is damaged it cannot be repaired and must be replaced with a new cord from th...

Page 5: ...cm clearance between the unit and any other objects or building structures and should be installed on a level surface The unit does not have to be vented outside during Dehumidifying or Fan Only mode operation Flexible Exhaust Hose 13cm Exhaust nozzle connector 2 pcs from 17 1 10 45cm up to 53 1 6 135cm Adjustable window door slider kit 3 pcs from 28 1 3 72cm up to 80 203cm Fixture 2 pcs Screws 12...

Page 6: ... level Note The air exchange h ose must vent outside the room when using cool mode Dehumidify Mode When dehumidify mode is selected the indicator light will shine ORANGE Air is dehumidified as it passes through the unit without being in full cooling mode The fan will operate on med speed If room temperature is 25 C 77 F fan speed can be adjusted otherwise fan speed is fixed to low Note The warm ai...

Page 7: ...hown in Fig F Otherwise fan speed is fixed to low NOTE The warm air exchange hoses must vent inside the room when using Dehumidifier Mode not outside as in Cooling Mode FAN Note During Fan Mode the exhaust hose does not have to be vented outdoors 1 Press the POWER SWITCH key to turn the unit on Fig A 2 Press the MODE key Fig B until the FAN indicator illuminates on the control panel Fig H Each pre...

Page 8: ...r keys To operate the hand held remote control you will require two AAA Alkaline batteries included Batteries should be replaced when a No signal beep is heard when attempting to program the main unit b The main unit does not respond to a command issued by the remote control Battery replacement 1 Slide the rear cover on the remote in the direction of the arrow Continue pulling gently until the cov...

Page 9: ...The air filter should be cleaned every two 2 weeks More frequent cleaning may be necessary depending on indoor air quality NOTE The air filter is located at the upper rear side of the unit 1 To remove the air filter Pull the air filter cover upward in the direction of the arrow Fig 4 and remove the air filter 2 Dust dirt clogged in the filter can be removed by vacuum cleaning the soiled areas 3 Th...

Page 10: ...mp is too high low Exhaust duct hose is blocked Contact your dealer This is normal Check the duct hose 4 Unit functions but the room is not cooled Window or door is open in room There is a heat source or too many people in the room Air intake grill is clogged Filter is too dirty Temperature setting is too high Close all windows doors Move any heat sources from room Clean air intake grill Replace t...

Page 11: ...ventilation indépendante Chacun des modes est équipé d une capacité de balayage de l air par oscillation Cet appareil peut être aisément déplacé d une pièce à l autre de la maison et il est installé en quelques minutes seulement Imaginez la commodité du confort au foyer 3 saisons à portée de la main en tout temps en tout lieu Pour la référence aisée nous vous suggérons de joindre une copie de votr...

Page 12: ... mises à la terre consultez un électricien qualifié 4 NE PAS UTILISER LES ADAPTATEURS DE FICHE OU LES CORDES DE RALLONGE AVEC CETTE UNITÉ S il est nécessaire d en utiliser une utiliser une corde de rallonge approuvée pour l usage avec les climatiseurs seulement disponible dans la plupart des quincailleries locales 5 Pour éviter la possibilité de blessure corporelle toujours débrancher l alimentati...

Page 13: ... utiliser le MODE DE VENTILATEUR à la position HAUTE MOYENNE ou BASSE Ceci fait circuler l air à l intérieur de la pièce pour fournir un certain confort de climatisation en utilisant moins d électricité 1 Branchez le cordon d alimentation à une prise d alimentation électrique 2 Le cordon d alimentation possède deux boutons situés sur la tête de la fiche L un des boutons est identifié par TEST et l...

Page 14: ...ge pour l ensemble d adapteurs de fenêtre Fig 2 1 Insérez le tube de raccord à travers l arriére du panneau de fenêtre 2 Fixez chaque tube de raccord avec quatre vis à travers l avant du panneau de fenêtre 3 Insérez les extensions de panneau de fenêtre dans le panneau de fenêtre Serrez légèrement les vis dans le panneau de fenêtre afin de maintenir les extensions en place Fig 3a Fig 3b 14 KIT DE F...

Page 15: ... désiré VENTILATEUR Sélectionnez à partir de trois réglages de ventilateur différent Haut Moyenne et Bas MINUTERIE AUTOMATIQUE Réglage de la MINUTERIE AUTOMATIQUE Arrêt automatique Lorsque l appareil est en fonction appuyez sur le bouton de la minuterie pour le réglage des commandes de la minuterie Appuyez sur ou pour sélectionner le nombre d heures que vous voulez que l appareil fonctionne avant ...

Page 16: ...auds d échange d air doivent exhaler à l intérieur de la salle en employant le mode déshumidifier pas extérieur comme en mode de refroidissement VENTILATEUR Note L installation du tuyau flexible pour l échappement d air n est pas requise pour le fonctionnement en mode de ventilation seulement 1 Appuyer sur la touche INTERRUPTEUR pour activer l unité Fig A 2 Appuyer sur la touche MODE Fig B jusqu à...

Page 17: ... la minuterie disponible est de 1 à 24 heures en appuyant sur la touche ou Deux piles alcalines AAA sont requises pour le fonctionnement de la télécommande incluses Les piles devraient être remplacées quand 1 Glisser le couvercle du compartiment des piles à l arriére de la télécommande dans le sens de la flèche Tirer délicatement jusqu à ce que le couvercle se sépare complètement de l unité 2 Insè...

Page 18: ...e selon la qualité de l air interne REMARQUE Le filtre à air est situé à la partie supérieure arrière de l unité 1 Pour enlever le filtre à air Tirez la couverture de filtre à air vers le haut dans la direction de la flèche Fig 4 et enlevez le filtre à air 2 La poussière saleté a obstrué dans le filtre peut être enlevée par le vide nettoyant les secteurs salis 3 Le filtre peut également être lavé ...

Page 19: ...onnante est trop élevée basse Le tuyau d échappement est bloqué Contactez votre marchand Ceci est tout à fait normal Vérifiez le tuyau d échappement 4 L unité fonctionne mais la pièce n est pas refroidie La fenêtre ou la porte de la pièce est ouverte Il y a une source de chaleur ou trop de gens dans la pièce La grille de prise d air est obstruée Le filtre est trop sale Le réglage de la température...

Page 20: ...e TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR PORTATIF Le numéro de modèle se trouve sur la plaque d information sur le panneau arrière de l appareil Toutes les pièces de rechange ou commandes spéciales sont disponibles à votre centre de service régional autorisé Pour obtenir ...

Reviews: