HOW TO REPLACE AN EMPTY CO2 CYLINDER

1. Close the main cylinder valve (A) by turning in a

clockwise direction. See Fig.13

2. Close the secondary shut-off valve (C) by 

turning to "horizontal" (east/west) position on 
lower stem pipe. See Fig.13

3. Remove the air line clamp and hose from the 

regulator.

4. Remove the regulator assembly (E) from empty 

cylinder. See Fig.13

5. Remove dust cap from new and/or replacement

CO2 cylinder

6. Re-attach regulator assembly (E) to

new/replacement cylinder. See Fig.13

7. Re-attach the air line hose to regulator (barb 

connection) and secure with clamp.

8. Slowly open main valve (A) all the way.

See Fig. 13

9. Readjust regulator pressure (D) (if necessary) 

between 10 ~ 12 psi/lbs.

10. Open the secondary shut-off valve (C)by turning

to "vertical" (north/south) position on lower stem
pipe.

SETTING THE REFRIGERATOR TEMPERATURE:

The temperature of the refrigerator compartment is
controlled by adjusting/setting the thermostat con-
trol knob, located on the ceiling of the refrigerator
cabinet. 

To start the refrigerator, and achieve maximum
cooling quickly;
• Turn the temperature control knob (using a coin 

or screwdriver) clockwise to the furthest 
(maximum) setting on the darker blue section of 
the graduated control dial.  See Fig. 14

• Allow the refrigerator to run at this setting for 3~4 

hours. 

• When maximum cooling is achieved, turn back 

the temperature control knob setting to the 2:00 
o'clock position on the graduated blue control 
dial. See Fig. 15

• Correct cooling temperature is a key factor to 

consider in storing and dispensing draught beer.

• Optimum temperature for serving draught beer is 

between 34ºF ~ 38ºF.(1ºC ~ 3ºC) 

• To maintain temperatures ranging between 

34ºF ~ 38ºF.(1ºC ~ 3ºC) We recommend the 
thermostat knob be positioned at the "2:00 
o'clock" setting on the graduated blue control dial. 
See Fig. 15

• To turn off the refrigerator, (no cooling) rotate the 

control knob to the "0" position. See Fig.14

Fig. 13

Fig. 14

Fig. 15

D

B

C

E

A

F

Summary of Contents for Millenium Chill'n Tap DKC445BL

Page 1: ...que d identification situ e sur le panneau arri re de l appareil Il est possible d acheter les pi ces de rechange ou de les obtenir par commande sp ciale en vous rendant votre service apr s vente le p...

Page 2: ...de s curit et les instructions d utilisation avant l utilisation initiale de ce produit PRECAUCI N Lea y observe todas las reglas de seguridad y las instrucciones de operaci n antes de usar este produ...

Page 3: ...erator application This refrigerator is for domestic use only and is intended for storing fresh foods at temperatures higher than 32 F 0 C Model Number ___________________________ Serial Number ______...

Page 4: ...et and or adjust the door IMPORTANT This appliance must be connected to a properly grounded electrical outlet see Grounding Instructions If food or beverage has a strange smell or color throw it away...

Page 5: ...om heat emitting sources This appliance is designed for indoor use only and should not be used outdoors This appliance is inclusive of an in wall static type condenser and should not be built in reces...

Page 6: ...lways connect CO2 gas cylinder to a regulator Failure to do so could result in an explosion with possible death or injury when the cylinder valve is opened 2 Never connect C02 gas cylinder directly to...

Page 7: ...the smaller screws at the front the larger screws at the rear 4 Installation of CO2 Cylinder Support Install the cylinder support onto the four studs located on the exterior back wall of the cabinet n...

Page 8: ...of the beer tower gasket and bayonet The beer faucet should be aligned with the F on the bayonet and facing the front of the cabinet 6 00 o clock position Using a Phillips Screwdriver attach the beer...

Page 9: ...20 Opening the CO2 Cylinder Main Valve Before opening the main valve located on top of the CO2 cylinder Make sure the secondary shut off valve located on the lower stem pipe of the regulator is in th...

Page 10: ...tor compartment is controlled by adjusting setting the thermostat con trol knob located on the ceiling of the refrigerator cabinet To start the refrigerator and achieve maximum cooling quickly Turn th...

Page 11: ...ost the refrigerator because ice depositing on the evaporator is defrosted automat ically Ice build up on the evaporator during compressor operation will when the compressor has cycled off defrost aut...

Page 12: ...ssive agitation occurs during transportation allow keg to settle for 1 2 hours before tapping Prior to tapping the keg ensure the beer faucet is in the off position Completely remove the dust cover id...

Page 13: ...oss the warmer ambient surfaces of the inner faucet Always make sure the faucet handle is pushed fully back closed to prevent excess dripping A beer faucet lock kit for the purpose of limiting access...

Page 14: ...he top of the cabinet 10 Install the Chill N Tap cabinet plug worktop 11 Install the 2 cantilever wire shelves onto the factory installed cantilever support brackets located on the rear wall of the re...

Page 15: ...hat Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance whether due to any defect of the appliance or its use whether proper or improper EXCLUSIO...

Reviews: