5
OPERATING INSTRUCTIONS
TIMER OPERATION
The timer will turn the light system on and off based
on the chosen settings, creating a regular light and
dark cycle for plants just as they would experience
when growing outdoors.
Different plants will grow best under different light
cycle conditions; some need more light and some
need less. Check the back of the seed packet for
information on the best light cycle to set for the
plants being grown.
To program the timer:
1. Press and hold the set button for 5 seconds until
“TS” appears on the display.
2. Press the up and down arrows to set the current
time to the nearest hour. The default time is
12:00 am, indicated by a ‘0’.
3. Once the current time is set, there are two preset
operating modes to choose from.
• Press the up arrow to choose preset P1.
• P1:
12 hour light cycle, meaning the lights
will be on for 12 hours and off for 12 hours.
• Press the down arrow to choose preset P2.
• P2:
18 hour light cycle, meaning the lights
will be on for 18 hours and off for 6 hours.
Note:
The timer is a 24 hour clock and can only be
set to the closest hour.
For example, if the current time is 3:45 pm, set
the clock to 16 indicating 4:00 pm. Always set the
current time to the nearest hour.
The timer will not display the current time. It uses the
set time as a guideline for the day and night cycle
and to count the hours before turning the light on or
off.
TIMER OPERATION
The preset modes can be altered by following the
steps below.
1. Press and hold the set button for 5 seconds until
“TS” appears on the display.
2. Press the set button repeatedly to choose from
the settings outlined in the below charts.
3. Use the up and down arrows to modify the
chosen setting.
Mode P1
H1
• The time when the light will turn on
• The default is 7:00 am
L1
• The number of hours that the light will remain on
• The default is 12 hours
Mode P2
H2
• The time when the light will turn on
• The default is 6:00 am
L2
• The number of hours that the light will remain on
• The default is 18 hours
Light Temperature Setting
T1
• The temperature at which the light will turn off
• Default: 32°C (90°F)
• Temperature range: 30°C - 35°C (86°F - 95°F)
T2
• The temperature at which the light will turn on
• Default: 30°C (86°F)
• Temperature range: 26°C - 34°C (79°F - 93°F)
Note:
T1 must be higher than T2
Fan Temperature Setting
F1
• The temperature at which the fan will turn off
• Default: 17°C (63°F)
• Temperature range: 16°C - 20°C (61°F - 68°F)
F2
• The temperature at which the fan will turn on
• Default: 19°C (66°F)
• Temperature range: 18°C - 22°C (64°F - 72°F)
Note:
F1 must be higher than F2