CARE & MAINTENANCE

AIR FILTER

The air fi lter should be cleaned approximately every 

2 weeks. The air fi lter may require more frequent 

cleaning if there is signifi cant dander or fur in the 

air.

Approximately every two weeks, the fi lter indicator 

light on the control panel will illuminate as a 

reminder to clean the fi lter. Follow the steps below 

to clean the fi lter and return the appliance to normal 

functioning.

1.  The air fi lter is located behind the rear intake 

grill. To remove the air fi lter, grasp the fi lter tab 

on the bottom of the grill and slide it downward. 

2.  Use a vacuum cleaner with a soft brush 

attachment to remove any large debris or dust 

build up from the air fi lter.

3.  Wash the fi lter in lukewarm, soapy water, below 

40°C (104°F), or use a neutral cleaning agent.

4.  Rinse the fi lter with clean water and dry 

thoroughly before reinstalling in the appliance.

5.  Press the fi lter button on the control panel to 

resume normal functioning.

Note:

 Do not operate the appliance without the air 

fi lter installed.

ERROR CODES

If the display panel shows any of the below error 

codes, unplug the appliance, let it stand for 5-10 

minutes and then plug it back in. If the error 

persists, call for service.

AS - Humidity sensor error

ES - Temperature sensor error

P2 - Full bucket or bucket not in the correct position

EC - Cooling sensor error or sensor error

CLEANING

To avoid possible electric shock, ensure that the 

appliance is unplugged before performing any 

cleaning or maintenance. 

The outside of the appliance can be wiped clean 

with a soft cloth or with a lukewarm, damp cloth if 

necessary.

Do not use gasoline, benzene, thinner or any 

other chemicals to clean this appliance as these 

substances can cause damage to the fi nish and 

deformation of plastic parts.

Never pour water directly onto the appliance as this 

will cause deterioration of electrical components 

and wiring insulation.

Ensure that the drain ports on the interior of the 

appliance and the drain ports on the back of the 

appliance are free of dirt and calcium build up.

Note:

 Do not clean the drain ports with anything 

more rigid than a pipe cleaner as this can damage 

the appliance. 

Note:

 If the drain ports are clogged or dirty it 

can cause water to leak from the bottom of the 

appliance.

END OF SEASON CARE

Before removing the appliance from service for the 

year, operate the appliance on high fan mode for 

half a day to ensure that the inside of the appliance 

is dry. This will help avoid the growth of mold or 

mildew inside the appliance. Ensure the fi lter is 

clean and dry. Store the appliance covered in a dry 

location.

DISPOSAL

This appliance may not be treated as regular 

household waste, it should be taken to the 

appropriate waste collection point for recycling of 

electrical components. Check for local regulatory 

compliance regarding approved and safe disposal 

of this appliance.

6

Summary of Contents for DDR030BDWDB

Page 1: ...L MANUEL DU PROPRI TAIRE MANUAL DEL PROPIETARIO DEHUMIDIFIER Owner s Manual 1 8 D SHUMIDIFICATEUR Manuel du propri taire 9 16 DESHUMIDIFICADOR Manual del propietario 17 24 MODEL MOD LE MODELO DDR030BD...

Page 2: ...ide the original purchase receipt to validate your warranty and receive service Model Number _________________________________________________ Serial Number ___________________________________________...

Page 3: ...use this dehumidi er for commercial or industrial applications GROUNDING INSTRUCTIONS This appliance must be grounded Grounding reduces the risk of electrical shock by providing an escape wire for th...

Page 4: ...e to allow for proper air circulation The recommended ambient operating temperature is between 5 C 41 F and 35 C 95 F Any time the appliance is placed on its back or side it must be allowed to stand u...

Page 5: ...ll automatically set the humidity and fan speed based on the ambient temperature and humidity The indicator light will illuminate when smart dehumidify is active OPERATING INSTRUCTIONS 4 5 Filter Butt...

Page 6: ...d water from the appliance 1 Water Bucket The dehumidi er will automatically collect condensed water in the water bucket When the bucket is full the compressor and fan will turn off and the full bucke...

Page 7: ...or error CLEANING To avoid possible electric shock ensure that the appliance is unplugged before performing any cleaning or maintenance The outside of the appliance can be wiped clean with a soft clot...

Page 8: ...t humidity Bucket is full or is not in the proper position Insuf cient dehumidifying Air lter is dirty Blocked air ow Appliance size is too small for application Ambient humidity is lower than the set...

Page 9: ...x 669 Findlay Ohio U S A 45840 Telephone 419 425 8627 FAX 419 425 8629 04 09 1 800 263 2629 Warranty Service In home Transportation charges to and from the service location are not protected by this w...

Page 10: ...re u d achat original pour valider votre garantie et recevoir le service Num ro de mod le _____________________________________________ Num ro de serie _______________________________________________...

Page 11: ...pas ce d shumidi cateur pour des applications commerciales ou industrielles INSTRUCTIONS DE MISE LA TERRE Cet appareil doit tre mis la terre La mise la terre r duit le risque de choc lectrique en fou...

Page 12: ...0 cm 16 pouces sur le dessus de l appareil pour permettre une circulation d air ad quate La temp rature ambiante de fonctionnement recommand e est comprise entre 5 C 41 F et 35 C 95 F Chaque fois que...

Page 13: ...t l humidit et la vitesse du ventilateur en fonction de la temp rature ambiante et de l humidit Le t moin lumineux s allume lorsque le d shumidi cation intelligent est activ INSTRUCTIONS D UTILISATION...

Page 14: ...param tres de la m moire y compris la minuterie ELIMINATION D EAU Il existe deux fa ons d liminer l eau collect e de l appareil 1 Seau d eau Le d shumidi cateur collectera automatiquement l eau conde...

Page 15: ...E Pour viter tout risque d lectrocution assurez vous que l appareil est d branch avant d effectuer un nettoyage ou une maintenance L ext rieur de l appareil peut tre nettoy avec un chiffon doux ou ave...

Page 16: ...bonne position La surface du plancher n est pas de niveau Odeurs Formation de moisissure sur des surfaces int rieures humides Placer un comprim d alga cide dans le seau eau L eau sur le sol Le raccord...

Page 17: ...t pas couverts par la pr sente garantie et doivent tre acquitt s par l acheteur Pendant les premiers vingt quatre 24 mois toutes les pi ces fonctionnelles de ce produit qui s av rent d fectueuses sero...

Page 18: ...ci n para obtener un servicio bajo garant a Debe proporcionar el recibo de compra original para validar su garant a y recibir servicio N mero de modelo _____________________________________________ N...

Page 19: ...DE CONEXION A TIERRA Este aparato debe estar conectado a tierra La puesta a tierra reduce el riesgo de descarga el ctrica proporcionando un cable de escape para la corriente el ctrica Este aparato tie...

Page 20: ...ior del electrodom stico para permitir una circulaci n de aire adecuada La temperatura de funcionamiento ambiente recomendada est entre 5 C 41 F y 35 C 95 F Cada vez que coloque el electrodom stico so...

Page 21: ...ustar autom ticamente la velocidad de la humedad y del ventilador en funci n de la temperatura ambiente y la humedad La luz indicadora se iluminar cuando el deshumidi cador inteligente est activo INST...

Page 22: ...REMOCION DE AGUA Hay dos formas de eliminar el agua recogida del aparato 1 Cubo de agua El deshumidi cador autom ticamente recoger agua condensada en el cubo de agua Cuando el cubo est lleno el compr...

Page 23: ...r del sensor LIMPIEZA Para evitar posibles descargas el ctricas aseg rese de que el aparato est desenchufado antes de realizar cualquier limpieza o mantenimiento El exterior del aparato se puede limpi...

Page 24: ...ire est sucio El cuchar n no est en la posici n adecuada Super cie del piso no nivelada Olores Formaci n de moho o moho en super cies mojadas internas Coloque una tableta algicida en el cubo de agua A...

Page 25: ...resulte defectuosa incluyendo cualquier sistema sellado ser reparado o reemplazado a opci n del fabricante sin cargo para el comprador original P ngase en contacto con el distribuidor donde adquiri el...

Page 26: ...___________________ __________________________________________________________________________________________ _________________________________________________________________________________________...

Page 27: ...___________________ __________________________________________________________________________________________ _________________________________________________________________________________________...

Page 28: ...m en Chine Impreso en China Danby Products Limited Guelph ON Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 DDR030BDWDB DDR045BDWDB DDR050BDWDB DDR060BDWDB DDR070BDWDB DDR030BDCWDB DDR045BDC...

Reviews: