INSTALLATION INSTRUCTIONS
5
Install Support Bracket:
1. Hold each support bracket fl ush against outside of sill, and tighten to bottom of cabinet as shown. in Fig. J¹.
Mark brackets at top level of sill, and remove.
2. Assemble sill anchor bracket to outside support legs at the market position, as seen in Fig. J² . Hand tighten,
but allow for any changes later. NOTE: Check that air conditioner is tilted downwards to the outside, about
3 ° to 4°, as shown in Fig. I. After installation, condensed water should not drain from the overfl ow drain hole
during normal use. If you notice water leaking out, check the angle of tilt, and make any necessary adjust-
ments. However, on a very humid day, water leakage can occur- this is normal. Measure the tilt angle from
the cabinet’s edge . The distance H should be approximately 1 1/4” to 1 5/8”.
3. Install support brackets (with sill anchor brackets attached) to correct hole in bottom of cabinet as shown in
Fig. K.
4. Tighten all 6 bolts securely.
Mark
Fig. J
1
Left
Locknut
Sill Anchor
Bracket
Flat Head
Bolt
2 Each Required For
Each Support Bracket
Right
1/2in.(12.7mm) Long
Left Screws And
Locknuts
Fig. J
2
Fig. K
Window Sill
Window Sash
$ERXWóWRǫ
Sill Angle Bracket
Side Louvers
Fig. I
Measure
the tilt
angle from
the cabinet’s
edge.
H
6
Extend Window FIller Panels
1. Extend panels to fi ll window opening completely. Secure the shutter clamp on each side of the (upper) shut-
ter and secure to window sill using one 7/16in. (12mm) locking screw and fl at washer on each side. (Fig. L).
2. Attach frame lock to window sill using one 13/16in. (20mm) screw on each side as shown in Fig. L.
3. Close window behind “L” bracket as seen in Fig. L.
7
Install Window Lock and Sash Seal
1. Trim sash seal to fi t window width. Insert into space between upper and lower sashes (Fig. M).
2. Attach right angle safety lock as shown in Fig. M.
16