Controller Integration 

When the Danalock has been included into the network, the controller should: 

 

Set the Lifeline. Association group 1 

 

Enable Notification for Access Control  

Test information  

Configuration Parameters 

When testing config parameter 4. Be aware that this is a count down, so a set and then a get will not return the 
same value.  

Battery Warning  

To get the lock to send a battery warning the voltage must be low AND the motor must be operated. The lock 
only measures the battery voltage under load to get the most precise result. By using a 1 A voltage adjustable 
transformer with approximately 1 meter of wire the following data has been collected.  

Voltage 

Battery report value 

12 V 

0x62 (98%) 

9V 

0x26 (38%) 

7,5V 

0x0B (11%) (Battery warning is send) 

No reports received  

If no reports are received from the lock it is most likely because the lock is not calibrated and thereby does not 
no know when the lock is lock or unlock and therefore it does not send reports to the gateway. There are two 
ways to calibrate the lock.  

1.

 

Autocalibration. Turn the Danalock manually until the door is unlocked and leave the door open while 
calibrating. Lift the handle if needed. Now click 3 times, after 5 seconds the Danalock will calibrate.  

2.

 

Manual calibration (start by turn to unlock). Turn the Danalock completely into unlock position, then 
click twice. Wait 5 seconds until it flashes yellow, then turn the Danalock into locked position and click 
once.  

 