Warning !!!
During cleaning and service the hand dryer
must always be disconnected from the power
supply
Cleaning the inside of the machine
1. Disconnect power supply.
2. Disassemble cover by removing the two cover
screws at the bottom of the housing. Use the
special Allen key which was originally supplied
with the hand dryer.
3. Disassemble angle bracket.
4. Loosen the 4 screws
on the fan housing
and disassemble fan
housing lid
5. Gently lift up the motor.
Be careful not to dama-
ge motor wiring.
6. Loosen carbon brush wiring.
9. Reassemble all components
and test run the hand dryer.
7.
Loosen the 2 x 2 screws,
allowing for the worn
brushes to be disassem-
bled from the motor.
8. Assemble new carbon
brushes and reassemble
screws and wires