Dametric
TVD-M2 / TVD-M3
TVD-M2-M3 EN.docx
May 26, 2011 / BL
7(8)
5.
CONNECTION
The cables are connected to the detachable
screw connectors at the bottom of the unit.
5.1 K1 - POWER SUPPLY
TVD-M2:
115-230 VAC Mains Voltage
Live
K1/1
Neutral
K1/6
TVD-M3:
24VDC Mains Voltage
Plus
K1/1
Minus
K1/4
5.2 K2 - ALARM OUTPUTS
Function normally normally
closed
open
com
Limit 1
K2/1
K2/2
K2/3
Limit 2
K2/4
K2/5
K2/6
Explanation. The above describes the state
of a not active output.
When the output is active (the led is lit and
the touch point level is lower than the limit
level)
the normally open contact is closed to the common contact.
5.3 K3 - LOGIC INPUT, TRANSDUCER, SIGNAL OUTPUT, GROUND
K3/1-2
Logic input, production
K3/1
Close this input to initiate production mode
K3/2
The input must be free from foreign potential
K3/3-5
Transducer signals
K-TVDS25, K-VIMS25
K3/3
Tran
white + brown
K3/4
Transducer -
green + yellow
K3/5
Transducer, cable shield
see below
K-TVDS25: Connect the shield to K3/5.
K-VIMS25: Isolate the inner shield. Connect the outer shield to K3/5
K3/6-8
Signal current output
K3/6
+ 4-20 mA
K3/7
common
K3/8
cable shield
K3/9
Ground
K3/9
Connect this pin direct to the protective ground close to the unit. Use a copper wire with
an area of 2.5 mm
2
.
5.4
K4 – HEADSET
Connect the cable from the headset (IR-HS) direct to the phono-contact in the upper part of the unit.
It is also possible to connect the cable K-HS5 between the headset and the unit
K1
K2
K3
K1
K2
K3
Pro-
duction
control
input
Signal
output
4-20mA
Trans-
ducer
cable
Limit 2
Relay
output
Limit 1
Relay
output
115 - 230 VAC
Mains supply
input
TVD-M2
VAL0123130
SKC9826773
gr
ou
nd
TVD Touchpoint Monitor
sh
ie
ld
sh
ie
ld
-
+
-
+
dametric
Serial:628
Pro-
duction
control
input
Signal
output
4-20mA
Trans-
ducer
cable
Limit 2
Relay
output
Limit 1
Relay
output
24 VDC
Power supply
input
TVD-M3
VAL0308989
gr
ou
nd
TVD Touchpoint Monitor
shie
ld
shie
ld
-
+
-
+
dametric
Serial:628