2. 

DESCRIPTION 

The TVD-M2/M3 monitors are used together with a vibration transducer to measure the touch point 
vibrations in a pulp refiner. 
The unit will work in the calibration mode or in the production mode. In the calibration mode the 
unit has the highest sensitivity to detect the touch point without unnecessary plate wear. 
In production mode, the unit will work with lower gain and will then work as a part in the plate clash 
protection system. The modes are selected by an input logic signal. 
The amplifier excites the transducer with a constant current. The transducer includes a built in signal 
conditioner, and the signal output is superimposed on the feeding constant current. The transducer 
signal is amplified, filtered and then monitored on both the front display and on the current signal 
output. 
The front display consists of a 20-segment led ramp and normally indicates the touch point signal 
level. 
The signal level is constantly compared with two adjustable alarm limit levels. The output is 
deactivated when the signal level exceeds the limit level, which is adjustable by one turn 
potentiometers.  
If any of the limit push buttons is pressed, the corresponding alarm limit is displayed on the internal 
led ramp and also monitored on the external analogue output. 
The signal can be attenuated for production mode by a closing of an input. A single turn 
potentiometer and a 4-pole dipswitch set attenuation and frequency response. 
The signal can be attenuated for compensation of different transducer location, different type of 
refiners and also the refiner main motor speed. A 4-pole dipswitch sets the attenuation.  
The signal level is also amplified to a headset output. The headset is connected to a phono contact on 
the top of the unit. The headset is used to listen to the actual touch point sound. The audible signal is 
not affected by the dip-settings for transducer location or production gain. 
The unit works together with four different type of transducers.  
The VIM-T2 for touch point frequencies between 200Hz and 10kHz. 
The TVD-T1 for touch point frequencies between 200Hz and 40kHz. This transducer is mounted on 
the TDC-transducer and is normally used in the CD-refiners. 
The TVD-T2 for touch point frequencies between 200Hz and 40kHz. The TVD-T2 is mounted on 
one of the bolts for the plate holder. 
The TVD-T2S has the same mounting method and frequency range as the VIM-T2 but has ten times 
higher sensitivity. This transducer is normally used in the Conflo refiner. 
There are two types of cables to be used between the unit and the transducers. The VIM-T2 uses the 
cable K-VIMS25 while all other transducers use the cable K-TVDS25. 
The TVD-M2 includes an AC/DC power unit, which converts and isolates the 115/230 VAC power 
supply to the in12V and -12V DC-voltages.  
The TVD-M3 is powered from a 24VDC source and includes a DC/DC converter for the internal 
supplies. 

 

Summary of Contents for TVD-M2

Page 1: ...D M2 M3 EN docx May 26 2011 BL 1 8 TVD M2 TVD M3 TOUCHPOINT VIBRATION MONITOR USERS MANUAL Contents 1 TECHNICAL SPECIFICATION 2 2 DESCRIPTION 3 3 HANDLING 4 4 SETTINGS 5 5 CONNECTION 7 6 TROUBLE SHOOTING 8 7 CONTACT 8 dametric ...

Page 2: ...ar graph scaled 0 100 5 per led Led yellow indicating active alarm limit outputs Led green indicating active production input Led green indicating power on Location attenuator Adjustable in 16 steps between 100 and 21 of normal gain Production attenuator Level Adjustable to 0 50 of normal gain by use of a single turn potentiometer Freq response See 4 4 Control input A closed input initiates the pr...

Page 3: ...uction mode by a closing of an input A single turn potentiometer and a 4 pole dipswitch set attenuation and frequency response The signal can be attenuated for compensation of different transducer location different type of refiners and also the refiner main motor speed A 4 pole dipswitch sets the attenuation The signal level is also amplified to a headset output The headset is connected to a phon...

Page 4: ... level than limit 1 Production Attenuator This potentiometer is used to change the attenuation during the production mode Usually the signal level will increase while the segment plates wears The potentiometer is used to adjust the touch point signal to a desirable level Limit 1 can then be used as a warning level while limit 2 can be used for interlocking The potentiometer has no effect in the ca...

Page 5: ...d in the front panel marked Production 4 2 1 Frequency response The dipswitch SW2 sets the frequency response during the production mode The response can be seen in the graphs on the following page The high pass filter can be set in the range of 0 3 to 19 kHz and is used to reduce the low frequency signals during production The higher frequency setting the higher the attenuation will be at lower f...

Page 6: ...ith 10 kHz transducer type setting a 0 3 kHz b 2 kHz c 4 kHz d 6 kHz e 8 kHz f 19 kHz 4 4 2 With 40 kHz transducer type setting a 0 3 kHz b 2 kHz c 4 kHz d 6 kHz e 8 kHz f 19 kHz 1k 10k 40k frequency gain 0 2 0 4 0 6 0 8 1 100 a b c d e f 1k 10k 40k frequency gain 0 2 0 4 0 6 0 8 1 100 a b c d e f ...

Page 7: ...ansducer white brown K3 4 Transducer green yellow K3 5 Transducer cable shield see below K TVDS25 Connect the shield to K3 5 K VIMS25 Isolate the inner shield Connect the outer shield to K3 5 K3 6 8 Signal current output K3 6 4 20 mA K3 7 common K3 8 cable shield K3 9 Ground K3 9 Connect this pin direct to the protective ground close to the unit Use a copper wire with an area of 2 5 mm2 5 4 K4 HEA...

Page 8: ... power supply must be shut off for at least 2 minutes The LED ramp is constantly indicating 100 Transducer fault or cable fault Is the cable connected to the transducer Check the transducer and the cable At normal conditions the nominal voltage across the transducer is about 10 5Vdc to K3 3 to K3 4 If the voltage is below 6 0V or above 15V the unit is defective 7 CONTACT Sales development producti...

Reviews: