GMS Industrial Router
GIR-DM1 EN.docx
Sept. 14, 2015 / BL
Page 5 of 7
3.2 Function of the control elements
Description
Operation
Meaning
Reset key
Press once for a short time.
Resets the software and restarts it.
(Soft reset)
Press at least 3 seconds.
Resets the hardware and restarts
it. (Hard reset)
Press three times for a short time
within 2 seconds.
Deletes all settings and resets the
device to the factory defaults.
SIM card slot
Press on SIM card for a short
time
Ejects the SIM card.
Table 3: Description of the functions and meaning of the control elements.
4 Connections
4.1 Front panel connections
Use this socket for the GIR Antenna
Ethernet cable to the switch
Figure 2: Connections on the front panel of the device
Position Description
1
Ethernet port LAN 1 (RJ45, 10/100 BT)
Connect this port to the GMS-SW1 unit.
2
Ethernet port LAN 2 (RJ45, 10/100 BT)
This port is normally not used.
3
Cellular antenna connection (SMA socket), main antenna.
Connect the GIR antenna to this socket.
4
Cellular antenna connection (SMA socket), additional antenna for 2x2 MIMO
(downlink). Normally not used.
Table 7: Description of the connections on the front panel of the device
The screen of the antenna system must be connected to the protective conductor when using an outside
mounted antenna.