Piranha4 2K and 4K Color Camera User's Manual
31
Teledyne DALSA
03-032-20180-05
Step 2. Connect Data, Trigger, and Power Cables
Note
: the u se of cables typ es and lengths other than those sp ecified m ay resu lt in increased em ission or
d ecreased im m u nity and p erform ance of the cam era.
Figure 22: Input and Output, trigger, and Power Connectors
WARN IN G! Grounding Instructions
Static electricity can d am age electronic com p onents. It’s critical that you d ischarge any static
electrical charge by tou ching a grou nd ed su rface, su ch as the m etal com p u ter ch assis, b efore
hand ling the cam era hard w are.
!
B
B
C
A
Power
+12V to +24V DC Hirose 6-pin
Control & Data
Camera Link 26-pin SDR26 connectors
Status
Diagnostic LED
A
B
B
C