68
•
Operational Reference
Linea SWIR GigE Series Camera
Exposure Delay
ExposureDelay The cP_FeaturesActivationMode feature
controls the exposure delay.
Gain
Gain The cP_FeaturesActivationMode feature
controls the Gain.
Flat Field Correction
FlatFieldCorrection The cP_FeaturesActivationMode feature
controls the flat field correction.
Output Lines
OutputLineControl The cP_FeaturesActivationMode feature
controls the output lines.
Features Activation Mode
cP_FeaturesActivationMode
Enables the selected feature to be part of the
cycling. When activating the selected feature,
this will automatically set the corresponding
standard camera feature to read only.
V1.00
Expert
DFNC
Off
Off Exclude the selected feature from the cycling.
Active
Active Activate the selected feature in the cycling.
Preset Configuration
Selector
cP_PresetConfigurationSelector
Selects the cycling preset to configure.
V1.00
Expert
DFNC
Exposure Time
cP_ExposureTime
Sets the exposure time (in microseconds) for
the selected set.
V1.00
Expert
DFNC
Gain
cP_Gain
Sets the selected gain as an amplification
factor applied to the image.
V1.00
Expert
DFNC
Flat Field Correction
Current Active Set
cP_flatfieldCorrectionCurrentActiveSet
Specifies the current set of Flat Field
coefficients to use.
V1.00
Expert
DFNC
User Flatfield 1
UserFlatfield1 Sets User Flat Field 1 coefficient table as the
current Flat Field.
User Flatfield 2
UserFlatfield2 Sets User Flat Field 2 coefficient table as the
current Flat Field.
User Flatfield 3
UserFlatfield3 Sets User Flat Field 3 coefficient table as the
current Flat Field.
User Flatfield 4
UserFlatfield4 Sets User Flat Field 4 coefficient table as the
current Flat Field.
Line Selector
cP_LineSelector
Selects which physical line (or pin) of the
external device connector to configure.
V1.00
Expert
DFNC
Line 3 or pin 6
Line2 Index of the physical line and associated
Output control block to use.
Line 4 or pin 8
Line4 Index of the physical line and associated I/O
control block to use.
Output Line Source
cP_OutputLineSource
Selects which internal signal, or event driven
pulse, or software control state to output on
the selected output line.
V1.00
Expert
DFNC
Off
Off Line output is Open.
Software Controlled
SoftwareControlled The OutputLineValue feature changes the
state of the output.
Pulse On: Start of
Exposure
PulseOnStartofExposure Generate a pulse on the ExposureStart event.
This option is typically used to trigger a strobe
light.
Output Line Value
cP_OutputLineValue
Sets the output state of the selected Line if
the outputLineSoftwareLatchControl = OFF.
OutputLineSource must be
SoftwareControlled. If the
outputLineSoftwareLatchControl = Latch , the
state of the pin will change with the
outputLineSoftwareCmd command.
V1.00
Expert
DFNC
Active
Active Sets the Output circuit to closed.
Inactive
Inactive Sets the Output circuit to open.
Exposure Delay
cP_ExposureDelay
Sets the exposure delay (in microseconds) for
the selected set.
V1.00
Expert
DFNC