Linea SWIR GigE Series Camera
Linea SWIR GigE Series Overview
•
13
PRNU Derating Curve
The sensor profile shape changes as it approaches the maximum line rate for a given exposure
time. For best PRNU performance, the camera flat field calibration should be calibrated at the
target line rate and exposure time.
Figure 4: PRNU Derating Curve
-1.00%
-0.50%
0.00%
0.50%
1.00%
1.50%
2.00%
2.50%
3.00%
0
5000
10000
15000
20000
25000
30000
35000
40000
Ch
an
ge
in
re
sp
on
se
/u
ni
fo
rmi
ty
(%)
Line Rate (Lines/second)
Change in PRNU vs Line Rate
Pixel Response Non-Uniformity
Mean Change in Response