Camera Performance and Features
47
Figure 19. Relationship between the Camera Settings
Active Settings for Current Operation
Active settings are those settings used while the camera is running and include all unsaved
changes made by GenICam input to the settings.
These active settings are stored in the camera’s
volatile
memory and will be lost and cannot be
restored if the camera resets, is powered down, or loses power during operation.
To save these settings so that they can be restored next time you power up the camera, or to
protect against losing them in the case of power loss, you must save the current settings using the
user set save parameter. Once saved, the current settings become t he selected user set.
User Setting
The user setting is the saved set of camera configurations that you can customize, resave, and
restore. By default, the user settings are shipped with the same settings as the factory set.
The command user set save saves the current settings to non-volatile memory as a user set. The
camera automatically restores the user set configured as the default set when it powers up.
To restore a saved user set, set the user set selector to the set you want to restore and then select
the user set load parameter.
Factory Settings
The factory setting is the camera settings that were shipped with the camera and which loaded
during the camera’s first power-up. To load or restore the original factory settings, at any time,
select the factory setting parameter and then select the user set load parameter.
Note: By default, the user settings are set to the factory settings.
Facrory Setting
Active Setting
By GenIcam Command
1.
Select a ‘User Set’
2.
Initiate a ‘User Set Load’
User Setting
By GenIcam Command
1.
Select a ‘User Set’
2.
Initiate a ‘User Set Save’
By GenIcam Command
1.
Select a ‘Factory Set’
2.
Initiate a ‘User Set Load’
By GenIcam GenIcam Command
1.
Select ‘Default Set’ as Factory
(Saves Automatically)
By GenIcam Command
1.
Select ‘Default Set’ as Uset Set #
(Saves Automatically)
Power Up
Or Reset
Power Up
Or Reset
GenIcam Input