DALSA
Falcon XDR and HG Series Camera User's Manual
54
Serial Interface: How to Control the Camera
PRNU coefficients.
0
= PRNU coefficients disabled
1
= PRNU coefficients enabled
Notes:
The coefficient set that you are enabling or disabling is
determined by the
csn
value. Refer to the previous section for
an explanation of the
csn
command.
Example:
•
epc 1 1
3.9.4
Selecting the Calibration Sample Size
Serial Command: css
Setting the Number of Frames to Sample
Purpose:
Sets the number of frames to sample when performing
pixel coefficient calculations. Higher values cause
calibration to take longer but provide the most accurate
results.
Syntax:
•
css i
Syntax Elements:
•
i
Number of frames to sample. Allowable values are
32
(default),
64
,
128
,
256
,
512
, or
1024
.
Notes:
To return the current setting, use the
gcp
command.
Example:
•
css 1024
3.9.5
Performing FPN Calibration
Serial Commands: ccf , sfc
Calibrating All Camera Pixels
Purpose:
Performs FPN calibration and eliminates FPN noise by
subtracting away individual pixel dark current.
Syntax:
•
ccf
Summary of Contents for Falcon 1.4M100 XDR Monochrome
Page 28: ...DALSA Falcon XDR and HG Series Camera User s Manual 28 Camera Hardware Interface...
Page 70: ...DALSA Falcon XDR and HG Series Camera User s Manual 70 Optical and Mechanical Considerations...
Page 74: ...DALSA Falcon XDR and HG Series Camera User s Manual 74 Troubleshooting...
Page 90: ...DALSA Falcon XDR and HG Series Camera User s Manual 90 Appendix C EMC Declaration...
Page 92: ...DALSA Falcon XDR and HG Series Camera User s Manual 92 Technical Support...