Falcon XDR and HG Series Camera User's Manual
DALSA
Serial Interface: How to Control the Camera
53
3.9.2
Selecting Factory or User Coefficients
Serial Command: csn
Purpose:
Selects the coefficient set to use. The camera ships with a
factory calibrated set of FPN and PRNU coefficients. The
factory coefficients cannot be erased or modified.
Syntax:
•
csn i
Syntax
Elements:
•
i
Coefficient set to use.
0
= Factory calibrated set of FPN and PRNU coefficients.
These coefficients cannot be erased or modified.
1
= User calibrated set of FPN and PRNU coefficients.
These coefficients
can
be deleted or modified.
Notes:
The camera ships with the factory calibrated FPN and PRNU
coefficients saved to both set 0 and set 1. When you first boot
up the camera, the camera operates using set 1 (
csn 1
)
enabled.
To retrieve the current coefficient set number, use
get csn
.
Example:
•
csn 0
3.9.3
Enabling Pixel Coefficients
Serial Command: epc
Purpose:
The camera ships with the FPN and PRNU coefficients
enabled, but you can enable and disable FPN and PRNU
coefficients whenever necessary.
Syntax:
•
epc i1 i2
Syntax
Elements:
•
i1
FPN coefficients.
0
= FPN coefficients disabled
1
= FPN coefficients enabled
•
i2
Summary of Contents for Falcon 1.4M100 XDR Monochrome
Page 28: ...DALSA Falcon XDR and HG Series Camera User s Manual 28 Camera Hardware Interface...
Page 70: ...DALSA Falcon XDR and HG Series Camera User s Manual 70 Optical and Mechanical Considerations...
Page 74: ...DALSA Falcon XDR and HG Series Camera User s Manual 74 Troubleshooting...
Page 90: ...DALSA Falcon XDR and HG Series Camera User s Manual 90 Appendix C EMC Declaration...
Page 92: ...DALSA Falcon XDR and HG Series Camera User s Manual 92 Technical Support...