Falcon XDR and HG Series Camera User's Manual
DALSA
Appendix B: Error Handling and Command List
85
Syntax
Command
Params
Description
smm
set mirroring
mode"
i
Enables or disables mirroring mode:
0
: disabled
1
: enabled
sot
set output
throughput
m
Sets the output throughput. Possible values are
80
or
160
MHz.
spc
Set PRNU
coefficient
x y i
x
= 1-1400
y
= 1-1024
i
= 0-255
ssb
Set subtract
background
t i
t
= 0-0
i
= 0-511
ssf
set sync
frequency
f
Sets the frame rate in Hz to a value from
0.095
to
102.354
.
ssg
set system gain
t i
Sets the digital gain.
t
= Tap selection. Allowable value is
0
for all taps.
i
= Gain value is specified from
0
to
65535
. The digital
video values are multiplied by this number.
svm
set video mode
m
Sets the camera’s video mode.
0
: Video mode
4
: Test pattern horizontal ramp
5
: Test pattern vertical ramp
6
: Test pattern diagonal ramp
7
: Test pattern FPN
8
: Test pattern PRNU
upd
upload CBF file
Updates the camera firmware with the selected file
vt
verify
temperature
Returns the current temperature of the camera.
vv
verify voltage
Returns the 1.2 V, 2.5V, and 3.3V measurements.
wct
Write calibration
temperature
f
To be used each time the camera is calibrated. Use vt to
verify camera temperature at calibration and use wct to
save the calibration temperature. The allowable range is
0.0 to 99.9.
Summary of Contents for Falcon 1.4M100 XDR Monochrome
Page 28: ...DALSA Falcon XDR and HG Series Camera User s Manual 28 Camera Hardware Interface...
Page 70: ...DALSA Falcon XDR and HG Series Camera User s Manual 70 Optical and Mechanical Considerations...
Page 74: ...DALSA Falcon XDR and HG Series Camera User s Manual 74 Troubleshooting...
Page 90: ...DALSA Falcon XDR and HG Series Camera User s Manual 90 Appendix C EMC Declaration...
Page 92: ...DALSA Falcon XDR and HG Series Camera User s Manual 92 Technical Support...