112
•
Declarations of Conformity
Xtium2-CL MX4 User's Manual
•
RS-422 differential line receiver used is am26lv32.
•
Maximum input signal frequency is 5
MHz.
•
The Xtium2-CL provides ESD filtering on-board.
•
See Line Trigger Source Selection for Line scan Applications for more information.
•
Refer to Sapera parameters:
CORACQ_PRM_SHAFT_ENCODER_ENABLE
CORACQ_PRM_SHAFT_ENCODER_LEVEL
CORACQ_PRM_SHAFT_ENCODER_DROP
or refer to
CORACQ_PRM_EXT_LINE_TRIGGER_ENABLE
CORACQ_PRM_EXT_LINE_TRIGGER_DETECTION
CORACQ_PRM_EXT_LINE_TRIGGER_LEVEL
CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE
•
See also *.cvi file entries:
Shaft Encoder Enable, Shaft Encoder Pulse Drop,
or see External Line Trigger Enable, External Line Trigger Detection, External Line Trigger Level,
External Line Trigger Source.
•
For TTL signal, connect directly to RS-422 (+) input.
•
For single ended signals, connect a bias voltage to the RS-422 (-) input to ensure correct
detection of the logic state of the signal connected to the RS-422 (+) input.
•
See the following section for connection methods.