background image

48

 

Rev. 1.0.0 | © 2019 Dallmeier | www.dallmeier.com 

MDF5450HD-DN Commissioning

13 

Technical Product Specification (Basic Data)

Interfaces

Video preview output

1× HDMI Micro port (Type D)

Audio Line IN (stereo)

1× 3.5 mm phone jack (for stereo TRS plug):
Input level: max. 2.83 V

p-p

Input impedance: 29 kΩ

Audio Line OUT (stereo)

1× 3.5 mm phone jack (for stereo TRS plug):
Output level at 10 kΩ load: max. 3.11 V

p-p

Output impedance: 320 Ω

Ethernet

1× RJ45 jack (female connector):

• 

10BASE-T

• 

100BASE-TX

• 

PoE (IEEE 802.3af)

Power IN

1× Weidmüller male connector SL 3.50/02/90G (mating connector: Weidmüller plug-in connector BL 3.50/02/180 SN)

Memory card slot

1× (microSDXC compatible)

Additional Features

Ambient light sensor

Summary of Contents for MDF5450HD-DN

Page 1: ...007810 Rev 1 0 0 2019 10 30 English MDF5450HD DN Commissioning ...

Page 2: ... View California USA HDMI of HDMI Licensing LLC headquartered in Sunnyvale California USA JavaScript of Oracle Corporation and or its affiliates headquartered in Redwood Shores California USA microSDXC of SD 3C LLC headquartered in North Hollywood California USA Microsoft Internet Explorer Microsoft Edge and Windows of Microsoft Corporation headquartered in Redmond Washington USA Mozilla and Firef...

Page 3: ...e of Delivery 11 Transportation and Packaging 11 Warranty 11 Appropriate Use 12 Operation 13 Approvals Certifications 13 6 Requirements 14 Ambient Conditions 14 Power Supply 15 7 Maintenance Inspection and Cleaning 17 8 Installation and Commissioning 18 9 Interfaces 38 10 Inserting a Memory Card 40 11 Pin Assignment 42 12 Connection First Time Access and Login 44 13 Technical Product Specification...

Page 4: ...lly and thoroughly before using the device Always observe and follow the contained instructions notes and warnings as well as the technical data in the currently valid product specification Keep all documents in legible condition and in a suitable location for future reference Regularly check the website www dallmeier com for the latest product documentation updates This Document Commissioning The...

Page 5: ...istics of the device The target audience of the document is trained system integrators installation contractors of video security surveillance systems Configuration The document entitled Configuration contains detailed information concerning the configuration of the device The target audience of the document is trained system integrators installation contractors of video security surveillance syst...

Page 6: ...sult in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE addresses practices not related to physical injury and indicates measures to prevent device and or property damage due to improper inst...

Page 7: ...rry out instructions one after the other in the sequence described Expressions in quotation marks usually refer to individual components of the device housing parts mounting elements connections interfaces etc or to control elements of the device s web based graphical user interface menu items buttons etc Paragraphs in italics provide information on basic principles special features and efficient ...

Page 8: ...ical appliances Periodic inspection on electrical appliances General requirements for electrical safety Regulations The use of video and audio security surveillance systems is in general strictly regulated Before using the device inform yourself about the currently valid laws and regulations regarding data worker and environmental protection and ensure compliance with them System Components Only u...

Page 9: ...se malfunctions and damage In this case wait until the device has reached room temperature up to 8 hours before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection against over voltages as well as for the immunity of information and communication technology equipment to electromagnetic interferences EMI all pro...

Page 10: ...evice from the PoE enabled PSE port Contact the sales partner responsible for your area Burnt Smell from the Device If you notice burnt smell or a formation of smoke coming from the device immediately disconnect it from the power supply pull out the power plug or disconnect the device from the PoE enabled PSE port Contact the sales partner responsible for your area Opening the Device The device ma...

Page 11: ...ing template Product documentation The scope of delivery may differ depending on the ordered equipment device variant or country of destination Transportation and Packaging Store the original packaging for later transportation Dallmeier is not responsible for any damage resulting from unprofessional or improper transportation The device should only be shipped in the original packaging If the origi...

Page 12: ... compact dome housing the connected encoder unit into a separate box housing The device is designed for indoor installations in suspended ceilings and can be operated with Power over Ethernet PoE Class 0 IEEE 802 3af or powered by an external 24V DC power supply unit NOTICE Damage to the device due to unsuitable mounting location The device is exclusively designed for indoor use An outdoor install...

Page 13: ... Poor lighting can lead to an incorrect white balance Approvals Certifications The following approvals certifications were valid for the device at the time of this document s compilation CE FCC RCM UL DIN 50130 4 compliant Visit www dallmeier com for possible updates Note USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the ...

Page 14: ...nlight high heat radiation e g radiator improper ambient temperatures nearby strong radiation sources e g radio transmitters magnetic fields corrosive gases and liquids e g salt water insufficient air ventilation e g closed cabinet NOTICE Damage to the device due to unfavorable ambient conditions Use of the device under unfavorable ambient conditions may shorten its lifetime and may cause malfunct...

Page 15: ...nt grounding earthing of the device in accordance with the currently applicable DIN VDE and ISO standards in order to ensure the safety of persons protection against dangerous contact voltages NOTICE Damage to the device due to improper power supply Damage to electronic components or serious malfunctions Always ensure the correct polarity when connecting an external DC power supply unit Do not ope...

Page 16: ...ge and therefore the intensity of the electric field between the contacts rises sharply when un mating the jack plug connection The more un mating cycles are carried out under PoE load the higher the loss of contact material due to metal evaporation by electrical arcs which in turn accelerates the material erosion process on the contact surfaces Damaged contacts with an increased contact resistanc...

Page 17: ... NOTICE Damage to the outer surfaces of the device due to improper cleaning practices Clean the housing outside with a clean soft dry and antistatic cloth Do not use detergents Damage to the lens element due to improper cleaning practices Remove dust and other small particles from the lens element with a suitable bulb blower and or a special lens dust brush to avoid scratching the lens Do not use ...

Page 18: ...lling template with markings for the intended installation hole Ø 70mm and the required drill holes Ø 5mm when using anchors dowels Tool e g center punch or awl for marking drill hole locations through the drilling template Electrically powered jigsaw or hand saw e g drywall utility saw for circular cut outs or drilling machine with hole saw Ø 70mm the used tool type must be suitable for the parti...

Page 19: ...Rev 1 0 0 2019 Dallmeier www dallmeier com 19 Commissioning MDF5450HD DN A 20 30 B t 9mm or t 18mm t 9 18mm Suspended Ceiling Panel Thickness t ...

Page 20: ...with hole saw or a drywall utility saw When using an electrically powered jigsaw or a hand saw you should first draw a circle line with a radius of 35mm around the center point to ensure the specified diameter and roundness of the installation hole If necessary use the drilling template provided A Ø 70mm The drilling cutting entry point should always be on the later visible side of the ceiling pan...

Page 21: ... MDF5450HD DN Unscrew the housing ring counterclockwise from the dome housing If necessary use the provided hand tool as shown above to loosen the screw connection more easily NOTICE When using the provided hand tool be careful not to scratch the housing ring A ...

Page 22: ...essary use a small slotted screwdriver or similar to lift out the plastic cap at one of its notches as shown above NOTICE Proceed with caution when lifting out the plastic cap with a screwdriver Be careful not to scratch the housing wrap a protective tape around the screwdriver if necessary and not to damage any components A ...

Page 23: ...issioning MDF5450HD DN Pass the encoder unit through the ceiling panel and insert the dome housing into the installation hole Before inserting the dome housing make sure that both retaining wings are swiveled in left picture default position ex works A ...

Page 24: ...x the dome housing in the ceiling panel To do this tighten the Phillips PH1 screw of both retaining wings with a suitable screwdriver in clockwise direction until both retaining wings swivel out and the dome housing is firmly anchored in the ceiling panel see next page A 2 Phillips PH1 ...

Page 25: ...allmeier com 25 Commissioning MDF5450HD DN When removing the device at a later date the retaining wings on the dome housing must be swiveled back to their default position by simply turn ing the corresponding screws counterclockwise ...

Page 26: ...eier www dallmeier com MDF5450HD DN Commissioning A Reinsert the plastic cap back to its original position in the dome housing When doing so ensure that the cylindrical mount for the ambient light sensor is aligned correctly ...

Page 27: ...ioning MDF5450HD DN A Screw the housing ring in clockwise direction back onto the dome housing as far as it will go Use the provided hand tool as shown above to tighten the housing ring NOTICE Be careful not to scratch the housing ring with the hand tool ...

Page 28: ... panel using 4 suitable screws e g chipboard screws with a diameter of 3 5mm so that the encoder unit is secured against slipping e g when replacing the ceiling panel NOTICE Pay attention to the suitable screw length depending on the panel thickness in order not to penetrate the ceiling panel on the later visible side Ø 3 5mm 2mm ...

Page 29: ...ommissioning MDF5450HD DN A Observe the chapter Interfaces on page 38 Connect the required cables and finally establish the power supply via PoE or by an external power supply unit The device starts up and is ready for operation after a few minutes ...

Page 30: ... 0 0 2019 Dallmeier www dallmeier com MDF5450HD DN Commissioning Ø 5mm 3 Ø 70mm B The drilling cutting entry point should always be on the later visible side of the ceiling panel Panel thickness t 9mm or t 18mm ...

Page 31: ...here Remove the drilling template from the ceiling panel Cut the installation hole with a diameter of exactly 70mm into the ceiling panel using a suitable tool e g a drilling machine with hole saw or a drywall utility saw When using an electrically powered jigsaw or a hand saw you should first draw a circle line with a radius of 35mm around the center point to ensure the specified diameter and rou...

Page 32: ...Commissioning Unscrew the housing ring counterclockwise from the dome housing If necessary use the provided hand tool as shown above to loosen the screw connection more easily NOTICE When using the provided hand tool be careful not to scratch the housing ring B ...

Page 33: ...t through the ceiling panel and insert the dome housing into the installation hole insert suitable anchors dowels into the existing drill holes beforehand if applicable Before inserting the dome housing make sure that both retaining wings are swiveled in left picture default position ex works B ...

Page 34: ...34 Rev 1 0 0 2019 Dallmeier www dallmeier com MDF5450HD DN Commissioning B Fix the dome housing with three suitable screws e g chipboard screws with a diameter of 3 4mm in the ceiling panel ...

Page 35: ...ioning MDF5450HD DN B Screw the housing ring in clockwise direction back onto the dome housing as far as it will go Use the provided hand tool as shown above to tighten the housing ring NOTICE Be careful not to scratch the housing ring with the hand tool ...

Page 36: ... panel using 4 suitable screws e g chipboard screws with a diameter of 3 5mm so that the encoder unit is secured against slipping e g when replacing the ceiling panel NOTICE Pay attention to the suitable screw length depending on the panel thickness in order not to penetrate the ceiling panel on the later visible side Ø 3 5mm 2mm ...

Page 37: ...ommissioning MDF5450HD DN B Observe the chapter Interfaces on page 38 Connect the required cables and finally establish the power supply via PoE or by an external power supply unit The device starts up and is ready for operation after a few minutes ...

Page 38: ...38 Rev 1 0 0 2019 Dallmeier www dallmeier com MDF5450HD DN Commissioning 9 Interfaces ⓐ ⓑ ⓒ ⓓ ⓔ ⓕ ...

Page 39: ...er unit The orientation of your device s RJ45 jack may differ from the figure previously shown ⓕ LAN PoE RJ45 jack PoE conformity IEEE 802 3af ⓓ Video preview output HDMI Micro port Type D ⓔ Memory card slot microSDXC compatible ⓐ Power IN Weidmüller male connector SL 3 50 02 90G ⓑ Audio Line IN 3 5mm phone jack for stereo TRS plug ⓒ Audio Line OUT 3 5mm phone jack for stereo TRS plug ...

Page 40: ...40 Rev 1 0 0 2019 Dallmeier www dallmeier com MDF5450HD DN Commissioning 10 Inserting a Memory Card ⓐ microSDXC card optional ⓐ ...

Page 41: ...amage to the device or memory card due to incorrect card insertion Make sure that the contacts of the used memory card are facing forward and upwards when inserting it into the memory card slot of the camera as shown in the preceding figure If necessary insert a suitable memory card into the microSDXC compatible memory card slot The memory card automatically locks into place by use of a spring mec...

Page 42: ...el Left channel Ring Right channel Right channel Sleeve Ground Ground 11 Pin Assignment Audio Line IN Line OUT each 3 5 mm phone jack for stereo TRS plug Audio Line OUT stereo Output level at 10kΩ load max 3 11Vp p Output impedance 320Ω Audio Line IN stereo Input level max 2 83Vp p Input impedance 29kΩ Audio Tip Ring Sleeve ...

Page 43: ...ower IN Weidmüller male connector SL 3 50 02 90G mating connector Weidmüller plug in connector BL 3 50 02 180 SN Power IN NOTICE Damage to the device due to improper power supply Damage to electronic components or serious malfunctions Always ensure the correct polarity when connecting an external DC power supply unit Do not operate the device with Power over Ethernet PoE if the device is powered b...

Page 44: ...erate the device with Power over Ethernet in this case a single port PoE injector is additionally required To configure the device the client PC must meet the following system requirements System Requirements Operating system OS Microsoft Windows 7 10 each with latest service pack Ethernet 100Mbps Web browser Microsoft Internet Explorer 11 Windows 7 Microsoft Edge Windows 10 Google Chrome Mozilla ...

Page 45: ...ce3 Ensure that your PC web browser can establish an Ethernet connection to your device if necessary contact your network administrator for more information and assistance Start the web browser Enter the IP address of your device into the address bar of the web browser Confirm the input The connection to the device is then established After the successful connection to the device and before the ve...

Page 46: ... user name admin The default password is the complete serial number of the device The serial number is printed on the type plate of the device and can also be determined using the Dallmeier software PService3 Enter the default password serial number of the device Enter a new password for the default administrator account and confirm your input the strength of the selected password is displayed dur...

Page 47: ...ode is displayed for authenticated and authorized users only The user name of the factory default administrator account is admin Enter your login credentials Click OK After a successful login the graphical user interface of the configuration mode is displayed Configure all required settings Finally click LOGOUT to properly log out of the device ...

Page 48: ...put level max 2 83Vp p Input impedance 29kΩ Audio Line OUT stereo 1 3 5mm phone jack for stereo TRS plug Output level at 10kΩ load max 3 11Vp p Output impedance 320Ω Ethernet 1 RJ45 jack female connector 10BASE T 100BASE TX PoE IEEE 802 3af Power IN 1 Weidmüller male connector SL 3 50 02 90G mating connector Weidmüller plug in connector BL 3 50 02 180 SN Memory card slot 1 microSDXC compatible Add...

Page 49: ...sions Approx Ø95 H49mm dome housing with lens sensor unit Approx W62 H42 D121mm encoder unit Cable length Approx 160mm between dome housing and encoder unit Weight Approx 270g dome housing with lens sensor unit Approx 400g encoder unit with cable Color Black with white housing ring Environmental Conditions Suitable installation sites Indoor Operating temperature 20 C to 50 C 4 F to 122 F Relative ...

Page 50: ...s Type CE FCC RCM UL DIN 50130 4 compliant The technical product specification basic data in this document is based on the information at the time of this document s compilation Detailed information and possible updates can be found in the currently valid product specification on www dallmeier com ...

Page 51: ......

Page 52: ...52 Rev 1 0 0 2019 Dallmeier www dallmeier com MDF5450HD DN Commissioning 14 Dimensions Ø 70mm Ø 23mm Ø 94 60mm 37 48mm 37 10mm 48 76mm Max 18mm Min 9mm ...

Page 53: ...Rev 1 0 0 2019 Dallmeier www dallmeier com 53 Commissioning MDF5450HD DN 62mm 57mm 57mm 121mm 5mm R 1 7 5 m m 12 50mm 32mm 12 50mm 111mm 136 60mm 36 60mm 100mm 41 50mm 2mm M3 M3 ...

Page 54: ......

Page 55: ......

Page 56: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com ...

Reviews: